BACKGROUND: Four-dimensional computed tomography (4D-CT) utilizes multiplanar images and perfusion characteristics to identify abnormal parathyroid glands. We assessed the role of 4D-CT in patients with inconclusive preoperative ultrasound and sestamibi localization studies.

METHODS: Adult patients with primary hyperparathyroidism with negative or discordant standard imaging who underwent both localization with 4D-CT and operative intervention for curative intent were included. Patient characteristics, 4D-CT scan results compared with operative findings, and curative proportion were assessed.

RESULTS: Of the 60 patients, 4D-CT accurately lateralized 73% and localized 60% of abnormal glands found at operation. Single candidate lesions (46/60) were confirmed at operation in 70%. When multiple lesions were identified on 4D-CT (14/60), accuracy dropped to 29% (P = .03). The accuracy of 4D-CT was not different between primary and reoperative cases (P = .79). Of the 8 patients with multigland disease diagnosed perioperatively, 5 had multiple candidate lesions noted on 4D-CT. In 94% (48/51) of patients, a >50% drop in intraoperative parathormone (IOPTH) level was achieved after resection and 87% (48/55) had long-term cure with a median follow-up of 221 days.

CONCLUSION: 4D-CT identifies the more than half of abnormal parathyroids missed by traditional imaging and should be considered in cases with negative or discordant sestamibi and ultrasound. Bilateral exploration is warranted when multiple candidate lesions are reported on 4D-CT. Multigland disease remains a challenging entity.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
21134543
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.