JOURNAL ARTICLE

Quantification of the upper and second sacral segment safe zones in normal and dysmorphic sacra

Michael J Gardner, Saam Morshed, Sean E Nork, William M Ricci, Milton L Chip Routt
Journal of Orthopaedic Trauma 2010, 24 (10): 622-9
20871250

OBJECTIVES: To quantify the obliquity and dimensions of the upper and second sacral segment iliosacral screw safe zones and to determine the differences between normal and dysmorphic sacral morphology.

DESIGN: Retrospective cohort.

SETTING: University Level I trauma center.

PATIENTS/PARTICIPANTS: Fifty patients with pelvic computed tomography scans.

INTERVENTION: All sacra were characterized as normal or dysmorphic based on plain pelvic radiographs and previously described criteria. Multiple computed tomography scan reconstructions were viewed and manipulated simultaneously with 6 degrees of freedom to allow for custom visualization in any plane.

MAIN OUTCOME MEASUREMENTS: In each patient, a unique reconstruction plane was created perpendicular to the safe zone axis. The narrowest safe zone cross-sectional area was measured. Next, on simulated pelvic outlet and inlet views, safe zone obliquity and width were measured. Finally, the space available for a transverse screw was assessed. Measurements were performed for both upper and second sacral segment. Values for normal and dysmorphic safe zones were compared.

RESULTS: Sacral dysmorphism was identified in 22 patients. In these sacra, the upper sacral segment safe zone cross-section was 36% smaller than in normal sacra (P < 0.001). No transverse screws could be placed, but accommodating for the caudal to cranial obliquity (30° versus 21° in normals, P < 0.001) and posterior to anterior obliquity (15% versus 4% in normals, P < 0.001) of the safe zone, an iliosacral screw at least 75 mm in length could be placed safely in 91% of patients. A transverse screw could be placed in 75% of normal sacra. In the second segment safe zone, the cross-sectional area was more than twice as large in dysmorphic sacra compared to normals (220 mm versus 109 mm, P < 0.001). The obliquity was not different on either the inlet or outlet views between groups. A transverse screw could be placed at this level in 95% of those with dysmorphic sacra and in only 50% of normal sacra.

CONCLUSIONS: Sacral dysmorphism occurred in 44% of patients in this consecutive series. Many anatomic differences were consistently found between the two morphologies with clinical relevance to iliosacral screw placement. Specifically, the dysmorphic upper sacral segment safe zone is significantly smaller and more obliquely oriented but is still large enough to accommodate an iliosacral screw in nearly all patients. The second sacral segment safe zone is approximately transversely oriented in both sacral types but is more than twice as large in dysmorphic sacra. This segment may be a primary fixation opportunity in patients with sacral dysmorphism.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
20871250
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"