Excluding pulmonary embolism in primary care using the Wells-rule in combination with a point-of care D-dimer test: a scenario analysis.
BMC Family Practice 2010
BACKGROUND: In secondary care the Wells clinical decision rule (CDR) combined with a quantitative D-dimer test can exclude pulmonary embolism (PE) safely. The introduction of point-of-care (POC) D-dimer tests facilitates a similar diagnostic strategy in primary care.We estimated failure-rate and efficiency of a diagnostic strategy using the Wells-CDR combined with a POC-D-dimer test for excluding PE in primary care.We considered ruling out PE safe if the failure rate was <2% with a maximum upper confidence limit of 2.7%.
METHODS: We performed a scenario-analysis on data of 2701 outpatients suspected of PE. We used test characteristics of two qualitative POC-D-dimer tests, as derived from a meta-analysis and combined these with the Wells-CDR-score.
RESULTS: In scenario 1 (SimpliRed-D-dimer sensitivity 85%, specificity 74%) PE was excluded safely in 23.8% of patients but only by lowering the cut-off value of the Wells rule to <2. (failure rate: 1.4%, 95% CI 0.6-2.6%)In scenario 2 (Simplify-D-dimer sensitivity 87%, specificity 62%) PE was excluded safely in 12.4% of patients provided that the Wells-cut-off value was set at 0. (failure rate: 0.9%, 95% CI 0.2-2.6%)
CONCLUSION: Theoretically a diagnostic strategy using the Wells-CDR combined with a qualitative POC-D-dimer test can be used safely to exclude PE in primary care albeit with only moderate efficiency.
METHODS: We performed a scenario-analysis on data of 2701 outpatients suspected of PE. We used test characteristics of two qualitative POC-D-dimer tests, as derived from a meta-analysis and combined these with the Wells-CDR-score.
RESULTS: In scenario 1 (SimpliRed-D-dimer sensitivity 85%, specificity 74%) PE was excluded safely in 23.8% of patients but only by lowering the cut-off value of the Wells rule to <2. (failure rate: 1.4%, 95% CI 0.6-2.6%)In scenario 2 (Simplify-D-dimer sensitivity 87%, specificity 62%) PE was excluded safely in 12.4% of patients provided that the Wells-cut-off value was set at 0. (failure rate: 0.9%, 95% CI 0.2-2.6%)
CONCLUSION: Theoretically a diagnostic strategy using the Wells-CDR combined with a qualitative POC-D-dimer test can be used safely to exclude PE in primary care albeit with only moderate efficiency.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app