Extracorporeal membrane oxygenation in postcardiotomy patients: factors influencing outcome.

OBJECTIVE: Our objective was to assess the morbidity and mortality in children requiring extracorporeal membrane oxygenator support after cardiac surgery and to determine factors influencing outcome.

METHODS: Between January 2003 and June 2008, 58 patients required extracorporeal membrane oxygenator support after cardiac surgery. A retrospective study was performed and factors influencing outcome were determined by logistic regression modeling with the probability of outcome based on a combination of multivariate predictors.

RESULTS: Median age and weight were 12 days and 3.3 kg, respectively. Thirty-one patients had single ventricle repair and 27 had biventricular repair. Median duration of support with the oxygenator was 6 days. Thirty-nine (67%) patients were successfully weaned off the support, but only 24 (41%) survived to hospital discharge. Chief complications were renal failure (31%), neurologic complications (29%), and sepsis (16%). Multivariable logistic regression analysis identified 10 days or more of extracorporeal membrane oxygenation (odds ratio = 6.1), urine output less than 2 mL x kg(-1) x h(-1) in first 24 hours (odds ratio = 15), renal failure (odds ratio = 9.4), and pH less than 7.35 after 24 hours of extracorporeal membrane oxygenation (odds ratio = 82) as significant independent factors associated with failure to wean off extracorporeal membrane oxygenation. Factors associated with failure of hospital discharge despite successful decannulation were as follows: extracorporeal membrane oxygenator support time of 10 days or more, red blood cell transfusion of greater than 1000 mL/kg during the entire period of oxygenator support, and sepsis. Patients with single ventricle repair were at higher risk of hospital mortality.

CONCLUSION: Longer duration of extracorporeal membrane oxygenator support, low pH and urine output in the first 24 hours, and renal failure are significant factors associated with mortality during extracorporeal membrane oxygenator support. Exposure to high amounts of blood transfusion during extracorporeal oxygenation, extended extracorporeal membrane oxygenator support, and sepsis increase risk of death after successful decannulation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app