OPEN IN READ APP
JOURNAL ARTICLE

Cardiac index measurements by transcutaneous Doppler ultrasound and transthoracic echocardiography in adult and pediatric emergency patients

H Bryant Nguyen, Daryl P Banta, Gail Stewart, Tommy Kim, Ramesh Bansal, James Anholm, William A Wittlake, Stephen W Corbett
Journal of Clinical Monitoring and Computing 2010, 24 (3): 237-47
20563629

INTRODUCTION: Non-invasive hemodynamic monitoring may facilitate resuscitation in critically ill patients. Validation studies examining a transcutaneous Doppler ultrasound technology, USCOM-1A, using pulmonary artery catheter as the reference standard showed varying results. In this study, we compared non-invasive cardiac index (CI) measurements by USCOM-1A with transthoracic echocardiography (TTE).

METHODS: This study was a prospective, observational cohort study at a university tertiary-care emergency department, enrolling a convenience sample of adult and pediatric patients. Paired measures of CI, stroke volume index (SVI), aortic outflow tract diameter (OTD), velocity time integral (VTI) were obtained using USCOM-1A and TTE. Pearson's correlation and Bland-Altman analyses were performed.

RESULTS: One-hundred and sixteen subjects were enrolled, with obtainable USCOM-1A CI measurements for 99 subjects (55 adults age 50 +/- 20 years and 44 children age 11 +/- 4 years) in the final analysis. Cardiac, gastrointestinal and infectious illnesses were the most common presenting diagnostic categories. The reference standard TTE measurements of CI, SVI, OTD, and VTI in all subjects were 3.08 +/- 1.18 L/min/m(2), 37.10 +/- 10.91 mL/m(2), 1.92 +/- 0.36 cm, and 20.36 +/- 4.53 cm, respectively. Intra-operator reliability of USCOM-1A CI measurements showed a correlation coefficient of r = 0.79, with 11 +/- 22% difference between repeated measures. The bias and limits of agreement of USCOM-1A compared to TTE CI were 0.58 (-1.48 to 2.63) L/min/m(2). The percent difference in CI measurements with USCOM-1A was 31 +/- 28% relative to TTE measurements.

CONCLUSIONS: The USCOM-1A hemodynamic monitoring technology showed poor correlation and agreement to standard transthoracic echocardiography measures of cardiac function. The utility of USCOM-1A in the management of critically ill patients remains to be determined.

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Available on the App Store

Available on the Play Store
Remove bar
Read by QxMD icon Read
20563629
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"