Iodine-123 metaiodobenzylguanidine imaging and carbon-11 hydroxyephedrine positron emission tomography compared in patients with left ventricular dysfunction

Ichiro Matsunari, Hirofumi Aoki, Yusuke Nomura, Nozomi Takeda, Wei-Ping Chen, Junichi Taki, Kenichi Nakajima, Stephan G Nekolla, Seigo Kinuya, Kouji Kajinami
Circulation. Cardiovascular Imaging 2010, 3 (5): 595-603
20534790

BACKGROUND: Although both (123)I-metaiodobenzylguanidine ((123)I-MIBG) imaging and (11)C-hydroxyephedrine ((11)C-HED) positron emission tomography (PET) are used for assessing cardiac sympathetic innervation, their relationship remains unknown. The aims were to determine whether (123)I-MIBG parameters such as heart-to-mediastinum ratio (H/M) are associated with quantitative measures by (11)C-HED PET and to compare image quality, defect size, and location between (123)I-MIBG single-photon emission computed tomography (SPECT) and (11)C-HED PET.

METHODS AND RESULTS: Twenty-one patients (mean left ventricular ejection fraction, 39 ± 15%) underwent (123)I-MIBG imaging and (11)C-HED PET. Early (15-minute), late (3-hour) H/M, and washout rate (WR) were calculated for (123)I-MIBG. Myocardial retention and WR was calculated for (11)C-HED. Using a polar map approach, defect was defined as the area with relative activity <60% of the maximum. Both the early (r=0.76) and late (r=0.84) (123)I-MIBG H/M were correlated with (11)C-HED retention. (123)I-MIBG WR was correlated with (11)C-HED WR (r=0.57). Defect size could not be measured in 3 patients because of poor quality (123)I-MIBG SPECT, whereas (11)C-HED defect was measurable in all patients. Although defect size measured by early or late (123)I-MIBG SPECT was closely correlated with that by (11)C-HED PET (early: r=0.94; late: r=0.88), the late (123)I-MIBG overestimated defect size particularly in the inferior and septal regions.

CONCLUSIONS: (123)I-MIBG H/M gives a reliable estimate of cardiac sympathetic innervation as measured by (11)C-HED PET. Furthermore, despite the close correlation in defect size, (11)C-HED PET appears to be more suitable for assessing regional abnormalities than does (123)I-MIBG SPECT.

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Available on the App Store

Available on the Play Store
Remove bar
Read by QxMD icon Read
20534790
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"