Interpreting lung function data using 80% predicted and fixed thresholds misclassifies more than 20% of patients.
Chest 2011 January
BACKGROUND: Differences in COPD classification have been shown in population data sets when using fifth percentiles as the lower limit of normal (LLN) vs the current GOLD (Global Initiative for Chronic Obstructive Lung Disease) guidelines of FEV(1)/FVC < 0.70 for detecting airway obstruction and an FEV(1) of 80% predicted for detecting and classifying the severity of COPD (GOLD/PP). Many lung function laboratories use 80% predicted to determine whether results are abnormal. Misclassification of the full range of lung diseases in large patient groups when using GOLD/PP criteria instead of the LLN has not been explored previously.
METHODS: We determined the discrepancy rates in pulmonary function test interpretation between the GOLD/PP and LLN methods on prebronchodilator lung function results from a large number of adult patients from the United Kingdom, New Zealand, and the United States.
RESULTS: In 11,413 patients, the GOLD/PP method misclassified 24%. Ten percent of patients who had normal lung function were falsely classified with a disease category, and 7% of patients were falsely attributed with emphysema. The GOLD/PP method gave false-positive classifications for airflow obstruction and restrictive defects to significantly more men (P < .01) and older patients (P < .0001) and also missed airflow obstruction and restrictive defects in younger patients (P < .0001).
CONCLUSIONS: Using lung function tests on their own with 80% predicted and fixed cut points to determine whether a test is abnormal could misdiagnose > 20% of patients referred for pulmonary function tests. The GOLD/PP method introduces clinically important biases in assessing disease status that could affect allocation to treatment groups. This misclassification is avoided by using the LLN based on the fifth-percentile values.
METHODS: We determined the discrepancy rates in pulmonary function test interpretation between the GOLD/PP and LLN methods on prebronchodilator lung function results from a large number of adult patients from the United Kingdom, New Zealand, and the United States.
RESULTS: In 11,413 patients, the GOLD/PP method misclassified 24%. Ten percent of patients who had normal lung function were falsely classified with a disease category, and 7% of patients were falsely attributed with emphysema. The GOLD/PP method gave false-positive classifications for airflow obstruction and restrictive defects to significantly more men (P < .01) and older patients (P < .0001) and also missed airflow obstruction and restrictive defects in younger patients (P < .0001).
CONCLUSIONS: Using lung function tests on their own with 80% predicted and fixed cut points to determine whether a test is abnormal could misdiagnose > 20% of patients referred for pulmonary function tests. The GOLD/PP method introduces clinically important biases in assessing disease status that could affect allocation to treatment groups. This misclassification is avoided by using the LLN based on the fifth-percentile values.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app