Combined system of fluorescence diffuse optical tomography and microcomputed tomography for small animal imaging.

We developed a dual-modality system that combines fluorescence diffuse optical tomography (fDOT) and flat panel detector-based microcomputed tomography (micro-CT) to simultaneously reveal molecular and structural information in small animals. In fDOT, a 748 nm diode laser was used as an excitation source, while a cooled charge coupled device camera was adopted to collect transmission fluorescence. In micro-CT, a flat panel detector based on amorphous silicon, with active area of 13 x 13 cm(2), and a microfocus x-ray tube were used. The fDOT system was mounted orthogonally to the micro-CT and the projection images were acquired without rotation of the sample, which is different from the method used for micro-CT alone. Both the finite element method and the algebraic reconstruction technique were used to reconstruct images from the fDOT. Phantom data showed that the resolution of the fDOT system was about 3 mm at an imaging depth of 7 mm. Quantitative error was no more than 5% and imaging sensitivity for 1,1(')-dioctadecyl-3,3,3('),3(')-etramethylindotricarbocyanine iodide bis-oleate (DiR-BOA) was estimated to be higher than 100 nM at a depth of 7 mm. Calculations of the phantom's center of mass showed that the location accuracy of fDOT was about 0.7 mm. We applied a Feldkamp algorithm to reconstruct the micro-CT image. By measuring the presampled modulation transfer function with a 30 microm tungsten thread, we estimated that the micro-CT has a resolution of 5 mm(-1) when the field of view was 6.5 cm. Our results indicate the uniformity of the transaxial micro-CT image and the contrast-to-noise ratio was measured as 1.95 for a radiation dose of 1 cGy. A non-image-based method was employed for merging images from the two imaging modalities. A nude mouse with DiR-BOA, imaged ex vivo, was used to validate the feasibility of the dual-modality system.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app