We have located links that may give you full text access.
Time trends in radiologists' interpretive performance at screening mammography from the community-based Breast Cancer Surveillance Consortium, 1996-2004.
Radiology 2010 July
PURPOSE: To examine time trends in radiologists' interpretive performance at screening mammography between 1996 and 2004.
MATERIALS AND METHODS: All study procedures were institutional review board approved and HIPAA compliant. Data were collected on subsequent screening mammograms obtained from 1996 to 2004 in women aged 40-79 years who were followed up for 1 year for breast cancer. Recall rate, sensitivity, and specificity were examined annually. Generalized estimating equation (GEE) and random-effects models were used to test for linear trend. The area under the receiver operating characteristic curve (AUC), tumor histologic findings, and size of the largest dimension or diameter of the tumor were also examined.
RESULTS: Data on 2,542,049 subsequent screening mammograms and 12,498 cancers diagnosed in the follow-up period were included in this study. Recall rate increased from 6.7% to 8.6%, sensitivity increased from 71.4% to 83.8%, and specificity decreased from 93.6% to 91.7%. In GEE models, adjusted odds ratios per calendar year were 1.04 (95% confidence interval [CI]: 1.02, 1.05) for recall rate, 1.09 (95% CI: 1.07. 1.12) for sensitivity, and 0.96 (95% CI: 0.95, 0.98) for specificity (P < .001 for all). Random-effects model results were similar. The AUC increased over time: 0.869 (95% CI: 0.861, 0.877) for 1996-1998, 0.884 (95% CI: 0.879, 0.890) for 1999-2001, and 0.891 (95% CI: 0.885, 0.896) for 2002-2004 (P < .001). Tumor histologic findings and size remained constant.
CONCLUSION: Recall rate and sensitivity for screening mammograms increased, whereas specificity decreased from 1996 to 2004 among women with a prior mammogram. This trend remained after accounting for risk factors. The net effect was an improvement in overall discrimination, a measure of the probability that a mammogram with cancer in the follow-up period has a higher Breast Imaging Reporting and Data System assessment category than does a mammogram without cancer in the follow-up period.
MATERIALS AND METHODS: All study procedures were institutional review board approved and HIPAA compliant. Data were collected on subsequent screening mammograms obtained from 1996 to 2004 in women aged 40-79 years who were followed up for 1 year for breast cancer. Recall rate, sensitivity, and specificity were examined annually. Generalized estimating equation (GEE) and random-effects models were used to test for linear trend. The area under the receiver operating characteristic curve (AUC), tumor histologic findings, and size of the largest dimension or diameter of the tumor were also examined.
RESULTS: Data on 2,542,049 subsequent screening mammograms and 12,498 cancers diagnosed in the follow-up period were included in this study. Recall rate increased from 6.7% to 8.6%, sensitivity increased from 71.4% to 83.8%, and specificity decreased from 93.6% to 91.7%. In GEE models, adjusted odds ratios per calendar year were 1.04 (95% confidence interval [CI]: 1.02, 1.05) for recall rate, 1.09 (95% CI: 1.07. 1.12) for sensitivity, and 0.96 (95% CI: 0.95, 0.98) for specificity (P < .001 for all). Random-effects model results were similar. The AUC increased over time: 0.869 (95% CI: 0.861, 0.877) for 1996-1998, 0.884 (95% CI: 0.879, 0.890) for 1999-2001, and 0.891 (95% CI: 0.885, 0.896) for 2002-2004 (P < .001). Tumor histologic findings and size remained constant.
CONCLUSION: Recall rate and sensitivity for screening mammograms increased, whereas specificity decreased from 1996 to 2004 among women with a prior mammogram. This trend remained after accounting for risk factors. The net effect was an improvement in overall discrimination, a measure of the probability that a mammogram with cancer in the follow-up period has a higher Breast Imaging Reporting and Data System assessment category than does a mammogram without cancer in the follow-up period.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app