Efficacy and safety of TVT-O and TVT-Secur in the treatment of female stress urinary incontinence: 1-year follow-up.
International Urogynecology Journal 2010 October
INTRODUCTION AND HYPOTHESIS: To reduce complications of transobturator tension-free vaginal tape, single-incision devices were introduced in the last years. We here report a comparison between the tension-free vaginal tape-obturator (TVT-O) and the TVT-Secur techniques in terms of efficacy and safety.
METHODS: Eighty-four patients with stress urinary incontinence (SUI) were scheduled to undergo TVT-O or TVT-Secur. Duration of the procedure, subjective estimate of blood loss, intraoperative and postoperative complications, postoperative postvoidal residue (PVR), time to first voiding, and pain level were recorded. Urodynamic tests, PVR, Incontinence Questionnaire Short Form (ICIQ-SF), King's Health Questionnaire, and a urinary diary were performed before and 12 months after procedure.
RESULTS: No differences in terms of cure rate were observed between the two groups (81.6% vs. 83.8%). Complication rate in the TVT-Secur group was lower (8.1%) than in the TVT-O group (15.8%), but not significant.
CONCLUSIONS: Both techniques seem to be effective and safe, with a low incidence of complications in both groups.
METHODS: Eighty-four patients with stress urinary incontinence (SUI) were scheduled to undergo TVT-O or TVT-Secur. Duration of the procedure, subjective estimate of blood loss, intraoperative and postoperative complications, postoperative postvoidal residue (PVR), time to first voiding, and pain level were recorded. Urodynamic tests, PVR, Incontinence Questionnaire Short Form (ICIQ-SF), King's Health Questionnaire, and a urinary diary were performed before and 12 months after procedure.
RESULTS: No differences in terms of cure rate were observed between the two groups (81.6% vs. 83.8%). Complication rate in the TVT-Secur group was lower (8.1%) than in the TVT-O group (15.8%), but not significant.
CONCLUSIONS: Both techniques seem to be effective and safe, with a low incidence of complications in both groups.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app