BACKGROUND: Normal Doppler-derived hemodynamic data for mitral valve bioprostheses are limited.

METHODS: To establish parameters for identifying normal function for each of the 3 types of bioprostheses examined, we conducted a comprehensive, retrospective, two-dimensional, and Doppler echocardiographic assessment of 179 patients who underwent implantation of the Medtronic Hancock II or the Medtronic Mosaic (Medtronic, Inc, Minneapolis, MN) porcine mitral valve bioprosthesis or the Carpentier-Edwards Perimount (Edwards Lifesciences LLC, Irvine, CA) bovine pericardial mitral valve bioprosthesis.

RESULTS: All bioprostheses were normal by clinical examination, intraoperative transesophageal echocardiography, and postoperative transthoracic echocardiography. Regardless of valve type and body surface area, the pressure half-time was < 124 ms in all patients. Mean gradient < 9.5 mm Hg, mitral E velocity < 2.6 m/s, mitral valve prosthesis time-velocity integral < 69 cm, and ratio of the mitral valve prosthesis time-velocity integral to the left ventricular outflow tract time-velocity integral < 3.4 were recorded in nearly all patients.

CONCLUSION: These cutoff values (mean + 2 standard deviation) are specific, but not sensitive, for identifying mitral valve prosthesis dysfunction. Prostheses with hemodynamic values that are higher than these cutoff values are likely dysfunctional, but in select cases, mitral valve prosthesis dysfunction may be present even when hemodynamic values are lower than these thresholds.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app