Arthroscopic supraspinatus tendon repair with suture-bridging technique: functional outcome and magnetic resonance imaging

Christine Voigt, Christin Bosse, Rolf Vosshenrich, Arndt P Schulz, Helmut Lill
American Journal of Sports Medicine 2010, 38 (5): 983-91
20436053

BACKGROUND: The suture-bridging technique is a new arthroscopic technique to repair rotator cuff tears. Biomechanical advantages compared with double-row fixations have been described.

HYPOTHESIS: The authors hypothesized that arthroscopic suture-bridging repair of the supraspinatus tendon would result in a superior clinical outcome and lower retear rates compared with previously published results after double-row fixation.

STUDY DESIGN: Case series; Level of evidence, 4.

METHODS: Fifty-one consecutive patients, with a median age of 62 years (range, 37-76 years), who had undergone an arthroscopic suture-bridging repair of an isolated supraspinatus tendon tear were evaluated in this prospective study 4, 12, and a median of 24 months postoperatively. Subjective and functional outcome was assessed using the simple shoulder test and Constant score. With magnetic resonance imaging 12 months postoperatively, the tendon integrity and potential predictors of failures were evaluated.

RESULTS: The simple shoulder test scores improved significantly from 9 points (range, 1-12 points) at 4 months, to 12 points (range, 1-12 points) at 12 months, and 12 points (range, 5-12 points) at 24 months postoperatively. The Constant score increased significantly from preoperative 64% (range, 37%-92%) to 82% (range, 36%-100%) at 4 months, 96% (range, 49%-100%) at 12 months, and 96% (range, 64%-100%) at 24 months postoperatively. Magnetic resonance imaging 12 months after surgery showed retears in 28.9%. Two different types of retears could be observed: insufficiently healed and medially retorn supraspinatus tendons. The Constant score did not differ significantly between the groups with retears and intact repairs. A patient age of more than 60 years was found to influence tendon healing significantly.

CONCLUSION: The hypothesis, that arthroscopic suture-bridging repair of the supraspinatus tendon would result in a superior clinical outcome and lower retear rates compared with previously published results after double-row fixation, could not be confirmed. The functional outcome after the new suture-bridging technique was good and comparable with the reported results after double-row repair from the literature. A structural failure of tendon repair was not identical to clinical failure.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Available on the App Store

Available on the Play Store
Remove bar
Read by QxMD icon Read
20436053
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"