Percutaneous screw fixation of acetabular fractures with 2D fluoroscopy-based computerized navigation.

INTRODUCTION: The treatment of displaced acetabular fractures with formal open reduction and internal fixation has gained general acceptance. However, extensile exposure can lead to complications. Two-dimensional fluoroscopy-based computerized navigation for placement of percutaneous screw across non-displaced acetabular fractures has attracted interest by making use of stored patient-specific imaging data to provide real-time guidance in multiple image planes during implant placement. The purpose of the present study was to document early treatment results and complications associated with this new technique and evaluate its clinical application to displaced acetabular fractures amenable to closed or limited open reduction.

MATERIALS AND METHODS: Eighteen adult patients with 12 non-displaced and 8 displaced acetabular fractures were treated with percutaneous screw fixation under the guidance of a fluoroscopy-based navigation system. There were 14 men and four women with a mean age of 42.1 years (range 19-54 years). According to the AO and Orthopaedic Trauma Association Classification, there were nine 62-A3, five 62-B1, three 62-B2, and three 62-B3. The mean follow-up was 21 months (range 12-28 months). The mean time from injury to surgery was 4 days (range 2-7 days).

RESULTS: A total of 30 acetabular screws were inserted, including 21 anterior column screws and 9 posterior column screws. The average operation time was 24.6 min (range 16-47 min) from the image acquisition to wound closure. The average fluoroscopic time was 28.4 s (range 11-58 s). Compared to the final position of the screw, the average deviated distance of wire tip was 2.5 mm (range 1.1-3.6 mm) and the average trajectory difference was 2.45 degrees (range 1.5 degrees -4.6 degrees ). Maximal gap displacement averaged 10 mm (range 2-22 mm) preoperatively and 3 mm (range 0-5 mm) postoperatively; while maximal step displacement averaged 4 mm (range 1-10 mm) preoperatively and 2 mm (range 0-4 mm) postoperatively. One patient sustained a transient femoral nerve palsy and resolved 2 months after the operation. No superficial or deep infection occurred. Using the rating system of D'Aubigne and Postel, 13 patients had excellent results, 4 patients had good results, and 1 patient had a fair result.

CONCLUSION: Percutaneous screw fixation of acetabular fractures with 2D fluoroscopy-based navigation could be applied not only to non-displaced fractures but also to displaced fractures amenable to closed or limited open reduction.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app