We have located links that may give you full text access.
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Continuous glucose monitoring in newborn babies at risk of hypoglycemia.
Journal of Pediatrics 2010 August
OBJECTIVE: To determine the usefulness of continuous glucose monitoring in babies at risk of neonatal hypoglycemia.
STUDY DESIGN: Babies >/=32 weeks old who were at risk of hypoglycemia and admitted to newborn intensive care received routine treatment, including intermittent blood glucose measurement using the glucose oxidase method, and blinded continuous interstitial glucose monitoring.
RESULTS: Continuous glucose monitoring was well tolerated in 102 infants. There was good agreement between blood and interstitial glucose concentrations (mean difference, 0.0 mmol/L; 95% CI, -1.1-1.1). Low glucose concentrations (<2.6 mmol/L) were detected in 32 babies (32%) with blood sampling and in 45 babies (44%) with continuous monitoring. There were 265 episodes of low interstitial glucose concentrations, 215 (81%) of which were not detected with blood glucose measurement. One hundred seven episodes in 34 babies lasted >30 minutes, 78 (73%) of which were not detected with blood glucose measurement.
CONCLUSION: Continuous interstitial glucose monitoring detects many more episodes of low glucose concentrations than blood glucose measurement. The physiological significance of these previously undetected episodes is unknown.
STUDY DESIGN: Babies >/=32 weeks old who were at risk of hypoglycemia and admitted to newborn intensive care received routine treatment, including intermittent blood glucose measurement using the glucose oxidase method, and blinded continuous interstitial glucose monitoring.
RESULTS: Continuous glucose monitoring was well tolerated in 102 infants. There was good agreement between blood and interstitial glucose concentrations (mean difference, 0.0 mmol/L; 95% CI, -1.1-1.1). Low glucose concentrations (<2.6 mmol/L) were detected in 32 babies (32%) with blood sampling and in 45 babies (44%) with continuous monitoring. There were 265 episodes of low interstitial glucose concentrations, 215 (81%) of which were not detected with blood glucose measurement. One hundred seven episodes in 34 babies lasted >30 minutes, 78 (73%) of which were not detected with blood glucose measurement.
CONCLUSION: Continuous interstitial glucose monitoring detects many more episodes of low glucose concentrations than blood glucose measurement. The physiological significance of these previously undetected episodes is unknown.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app