Journal Article
Multicenter Study
Add like
Add dislike
Add to saved papers

The use of capnography and the availability of airway equipment on Intensive Care Units in the UK and the Republic of Ireland.

Anaesthesia 2010 May
At least 20% of reported major adverse airway events occur on the intensive care unit. This study surveyed 315 (96%) of all general, satellite, hepatobiliary, cardiac and neuro-intensive care units in the UK and the Republic of Ireland, finding that only 100 (32%) units always use capnography for tracheal intubation while only 80 (25%) always use capnography for continuous monitoring of patients requiring controlled ventilation. Three hundred and ten (98%) units utilise a checklist of airway equipment, 311 (99%) check its functionality on a daily basis and 296 (94%) units have access to a bronchoscope. Whilst 297 (94%) ICUs have an airway trolley, sufficient equipment for unanticipated difficult intubation was only seen on 33 (10%) of units. Guidelines addressing minimum standards for monitoring and airway safety on ICU are not being met and remain below the standard expected.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app