Journal Article
Multicenter Study
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Mechanical dispersion assessed by myocardial strain in patients after myocardial infarction for risk prediction of ventricular arrhythmia.

OBJECTIVES: The aim of this study was to investigate whether myocardial strain echocardiography can predict ventricular arrhythmias in patients after myocardial infarction (MI).

BACKGROUND: Left ventricular (LV) ejection fraction (EF) is insufficient for selecting patients for implantable cardioverter-defibrillator (ICD) therapy after MI. Electrical dispersion in infarcted myocardium facilitates malignant arrhythmia. Myocardial strain by echocardiography can quantify detailed regional and global myocardial function and timing. We hypothesized that electrical abnormalities in patients after MI will lead to LV mechanical dispersion, which can be measured as regional heterogeneity of contraction by myocardial strain.

METHODS: We prospectively included 85 post-MI patients, 44 meeting primary and 41 meeting secondary ICD prevention criteria. After 2.3 years (range 0.6 to 5.5 years) of follow-up, 47 patients had no and 38 patients had 1 or more recorded arrhythmias requiring appropriate ICD therapy. Longitudinal strain was measured by speckle tracking echocardiography. The SD of time to maximum myocardial shortening in a 16-segment LV model was calculated as a parameter of mechanical dispersion. Global strain was calculated as average strain in a 16-segment LV model.

RESULTS: The EF did not differ between ICD patients with and without arrhythmias occurring during follow-up (34 +/- 11% vs. 35 +/- 9%, p = 0.70). Mechanical dispersion was greater in ICD patients with recorded ventricular arrhythmias compared with those without (85 +/- 29 ms vs. 56 +/- 13 ms, p < 0.001). By Cox regression, mechanical dispersion was a strong and independent predictor of arrhythmias requiring ICD therapy (hazard ratio: 1.25 per 10-ms increase, 95% confidence interval: 1.1 to 1.4, p < 0.001). In patients with an EF >35%, global strain showed better LV function in those without recorded arrhythmias (-14.0% +/- 4.0% vs. -12.0 +/- 3.0%, p = 0.05), whereas the EF did not differ (44 +/- 8% vs. 41 +/- 5%, p = 0.23).

CONCLUSIONS: Mechanical dispersion was more pronounced in post-MI patients with recurrent arrhythmias. Global strain was a marker of arrhythmias in post-MI patients with relatively preserved ventricular function. These novel parameters assessed by myocardial strain may add important information about susceptibility for ventricular arrhythmias after MI.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app