JOURNAL ARTICLE
RESEARCH SUPPORT, U.S. GOV'T, NON-P.H.S.
Add like
Add dislike
Add to saved papers

Is respiration-induced variation in the photoplethysmogram associated with major hypovolemia in patients with acute traumatic injuries?

Shock 2010 November
It has been widely accepted that metrics related to respiration-induced waveform variation (RIWV) of the photoplethysmogram (PPG) have been associated with hypovolemia in mechanically ventilated patients and in controlled laboratory environments. In this retrospective study, we investigated if PPG RIWV metrics have diagnostic value for patients with acute hemorrhagic hypovolemia in the prehospital environment. Photoplethysmogram waveforms and basic vital signs were recorded in trauma patients during prehospital transport. Retrospectively, we used automated algorithms to select patient records with all five basic vital signs and 45 s or longer continuous, clean PPG segments. From these segments, we identified the onset and peak of individual heartbeats and computed waveform variations in the beats' peaks and amplitudes: (1) as the range between the maximum and the minimum (max-min) values and (2) as their interquartile range (IQR). We evaluated their receiver operating characteristic (ROC) curves for major hemorrhage. Separately, we tested whether RIWV metrics have potential independent information beyond basic vital signs by applying multivariate regression. In 344 patients, RIWV max-min yielded areas under the ROC curves (AUCs) not significantly better than a random AUC of 0.50. Respiration-induced waveform variation computed as IQR yielded ROC AUCs of 0.65 (95% confidence interval, 0.54-0.76) and of 0.64 (0.51-0.75), for peak and amplitude measures, respectively. The IQR metrics added independent information to basic vital signs (P < 0.05), but only moderately improved the overall AUC. Photoplethysmogram RIWV measured as IQR is preferable over max-min, and using PPG RIWV may enhance physiologic monitoring of spontaneously breathing patients outside strictly controlled laboratory environments.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app