Correlation of Device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis.

OBJECTIVES: The aim of this study was to assess the influence of amount and distribution of calcifications of the aortic valve and the left ventricular outflow tract on the acute procedural outcome of patients undergoing transcatheter aortic valve implantation (TAVI).

BACKGROUND: Transcatheter aortic valve implantation is a new percutaneous technique especially for elderly, high-risk patients with significant aortic valve stenosis (AS). After TAVI, post-interventional paravalvular aortic regurgitations (PAR) can occur, which is believed to be related partially to valve calcifications.

METHODS: We prospectively analyzed 100 symptomatic patients with severe AS scheduled for TAVI with the CoreValve ReValving (Medtronic, Minneapolis, Minnesota) prosthesis. In all patients, a native and contrast-enhanced multislice cardiac computed tomography was performed pre-interventionally. Calcification load of the valve and the adjacent outflow tract was estimated by the Agatston Score (AgS), and the amount and distribution of calcification was semi-quantitatively assessed and graded on a 1 to 4 scale (device "landing zone" calcification score [DLZ-CS]). Aortography was performed to evaluate the PAR pre-interventionally, after initial device release (PAR0) and after termination of the procedure (PAR1). Transthoracic echocardiography was performed 2 weeks after implantation (PAR2).

RESULTS: The AgS and DLZ-CS showed a significant correlation with the grade of PAR0 (AgS: r = 0.329, p = 0.001; DLZ-CS: r = 0.356, p < 0.001), PAR1 (AgS: r = 0.254, p = 0.011; DLZ-CS: r = 0.240, p = 0.016), and PAR2 (AgS: r = 0.341, p = 0.001; DLZ-CS: r = 0.300, p = 0.002). Both scores (AgS and DLZ-CS) showed a significant positive correlation (r = 0.858, p < 0.001).

CONCLUSIONS: Calcification in the CoreValve device "landing zone" shows a significant positive correlation to PAR after TAVI. Furthermore, the need for "second maneuvers" (i.e., post-dilation after initial device release) can be predicted by these calcification scores (AgS and DLZ-CS).

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app