COMPARATIVE STUDY
JOURNAL ARTICLE
MULTICENTER STUDY

Comparison of functional outcome after volar plate fixation with 2.4-mm titanium versus 3.5-mm stainless-steel plate for extra-articular fracture of distal radius

J Sebastiaan Souer, David Ring, Stefan Matschke, Laurent Audige, Marta Maren-Hubert, Jesse Jupiter
Journal of Hand Surgery 2010, 35 (3): 398-405
20138716

PURPOSE: Open reduction and locked volar plate and screw fixation is a popular treatment method for extra-articular distal radius fractures with dorsal metaphyseal comminution. In this study, we compared the use of a titanium 2.4-mm precontoured plate with that of a stainless-steel oblique 3.5-mm T-shaped plate to test the null hypothesis that there would be no difference in wrist function or upper extremity-specific health status in the internal fixation of AO-type A3.2 distal radius fractures.

METHODS: We retrospectively analyzed 24 patients treated with a 2.4-mm titanium plate and 38 patients treated with a 3.5-mm stainless-steel plate for an extra-articular and dorsally angulated distal radius fracture, from data gathered in a prospective cohort study of plate and screw fixation of distal radius fractures. The 2 cohorts were analyzed for differences in motion, grip strength, pain, Gartland and Werley score, Disabilities of the Arm, Shoulder, and Hand score, and Short Form-36 score at 6, 12, and 24 months of follow-up. Group differences and their change over time were determined using regression analysis and the likelihood ratio test.

RESULTS: There were no significant differences in wrist function and arm-specific health status between patients treated with a 2.4-mm plate and those treated with a 3.5-mm plate at 6, 12, or 24 months of follow-up. However, we observed a trend toward greater wrist flexion at 1 year (66 degrees vs 55 degrees ; p=.07) and greater flexion-extension arc (137 degrees vs 123 degrees ; p=.08) and pronation-supination arc (172 degrees vs 160 degrees ; p=.07) at 24 months after surgery in patients treated with a 2.4-mm plate.

CONCLUSIONS: Patients with a dorsally angulated extra-articular distal radius facture can expect similar results when treated with either a precontoured 2.4-mm titanium plate or a 3.5-mm stainless-steel T-shaped plate.

TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic III.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
20138716
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"