CT Hounsfield units of brown adipose tissue increase with activation: preclinical and clinical studies.
Journal of Nuclear Medicine 2010 Februrary
UNLABELLED: Brown adipose tissue (BAT) densities assessed as CT Hounsfield units (HUs) were evaluated in a rodent model and in patients to determine whether HUs changed in relation to BAT activity.
METHODS: Serial (18)F-FDG PET/CT was performed on rats under both room temperature control conditions and after 4 h of cold-stimulation, which is known to activate BAT. The maximum standardized uptake values and CT HUs of BAT were measured, and tissues were examined in the laboratory. Image records from cancer patients who underwent PET/CT were reviewed, and 23 patients were identified who displayed both high and low (18)F-FDG uptake into BAT on serial (18)F-FDG PET/CT scans. The maximum standardized uptake values and CT HUs of BAT were compared in these scans.
RESULTS: The mean (+/-SD) CT HUs of cold-activated BAT (-12.4 +/- 22.4) were significantly higher than those (-27.9 +/- 9.6) of the controls in the rat model. The CT HUs of BAT (-71.6 +/- 18.0) in the patients with high (18)F-FDG uptake were significantly higher than those (-104.4 +/- 16.8) of the patients with low (18)F-FDG uptake . A decrease in relative lipid content is seen in activated BAT in rats on histology.
CONCLUSION: The CT HUs of BAT increased in activated conditions in both animals and patients, likely because of lipid consumption by activated BAT.
METHODS: Serial (18)F-FDG PET/CT was performed on rats under both room temperature control conditions and after 4 h of cold-stimulation, which is known to activate BAT. The maximum standardized uptake values and CT HUs of BAT were measured, and tissues were examined in the laboratory. Image records from cancer patients who underwent PET/CT were reviewed, and 23 patients were identified who displayed both high and low (18)F-FDG uptake into BAT on serial (18)F-FDG PET/CT scans. The maximum standardized uptake values and CT HUs of BAT were compared in these scans.
RESULTS: The mean (+/-SD) CT HUs of cold-activated BAT (-12.4 +/- 22.4) were significantly higher than those (-27.9 +/- 9.6) of the controls in the rat model. The CT HUs of BAT (-71.6 +/- 18.0) in the patients with high (18)F-FDG uptake were significantly higher than those (-104.4 +/- 16.8) of the patients with low (18)F-FDG uptake . A decrease in relative lipid content is seen in activated BAT in rats on histology.
CONCLUSION: The CT HUs of BAT increased in activated conditions in both animals and patients, likely because of lipid consumption by activated BAT.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app