Improving environmental hygiene in 27 intensive care units to decrease multidrug-resistant bacterial transmission.

OBJECTIVE: To determine the thoroughness of terminal disinfection and cleaning of patient rooms in hospital intensive care units and to assess the value of a structured intervention program to improve the quality of cleaning as a means of reducing environmental transmission of multidrug-resistant organisms within the intensive care unit.

DESIGN: Prospective, multicenter, and pre- and postinterventional study.

SETTING: Intensive care unit rooms in 27 acute care hospitals. Hospitals ranged in size from 25 beds to 709 beds (mean, 206 beds).

INTERVENTIONS: A fluorescent targeting method was used to objectively evaluate the thoroughness of terminal room cleaning before and after structured educational, procedural, and administrative interventions. Systematic covert monitoring was performed by infection control personnel to assure accuracy and lack of bias.

MEASUREMENTS AND MAIN RESULTS: In total, 3532 environmental surfaces (14 standardized objects) were assessed after terminal cleaning in 260 intensive care unit rooms. Only 49.5% (1748) of surfaces were cleaned at baseline (95% confidence interval, 42% to 57%). Thoroughness of cleaning at baseline did not correlate with hospital size, patient volume, case mix index, geographic location, or teaching status. After intervention and multiple cycles of objective performance feedback to environmental services staff, thoroughness of cleaning improved to 82% (95% confidence interval, 78% to 86%).

CONCLUSIONS: Significant improvements in intensive care unit room cleaning can be achieved in most hospitals by using a structured approach that incorporates a simple, highly objective surface targeting method and repeated performance feedback to environmental services personnel. Given the documented environmental transmission of a wide range of multidrug-resistant pathogens, our findings identify a substantial opportunity to enhance patient safety by improving the thoroughness of intensive care unit environmental hygiene.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app