JOURNAL ARTICLE

Minimising contralateral breast dose in post-mastectomy intensity-modulated radiotherapy by incorporating conformal electron irradiation

Hans Paul van der Laan, Erik W Korevaar, Wil V Dolsma, John H Maduro, Johannes A Langendijk
Radiotherapy and Oncology 2010, 94 (2): 235-40
20080312

PURPOSE: To assess the potential benefit of incorporating conformal electron irradiation in intensity-modulated radiotherapy (IMRT) for loco-regional post-mastectomy RT.

PATIENTS AND METHODS: Ten consecutive patients that underwent left-sided mastectomy were selected for this comparative planning study. Three-dimensional conformal radiotherapy (3D-CRT) photon-electron dose plans were compared to photon-only IMRT (IMRT(p)) and photon IMRT with conformal electron irradiation (IMRT(p/e)). The planning target volume (PTV) was prescribed 50 Gy and included the chest wall and the internal mammary and supra-clavicular lymph node regions. It was attempted to minimise dose delivered to heart, lungs and contralateral breast (CB), while maintaining adequate PTV coverage.

RESULTS: All plans complied with objectives for PTV coverage. IMRT(p/e) eliminated volumes receiving 70 Gy (V70) that were present in 3D-CRT at the junction of photon and electron beams. Both IMRT strategies reduced heart V30 significantly below 3D-CRT levels. Mean heart dose with IMRT(p/e) was the lowest and was equal to that with 3D-CRT. Minimising heart dose with IMRT(p) resulted in irradiated CB volumes much larger than that with 3D-CRT. With IMRT(p/e), CB dose was only slightly increased when compared to 3D-CRT. Mean lung dose values were similar for IMRT and 3D-CRT. With IMRT, lung V20 was smaller, whereas V5 values for heart, lung and CB were higher than those with 3D-CRT.

CONCLUSIONS: Incorporation of conformal electron irradiation in post-mastectomy IMRT(p/e) enables a heart dose reduction which can only be obtained with IMRT(p) when allowing large irradiated volumes in the contralateral breast.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
20080312
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"