JOURNAL ARTICLE

Type III tympanoplasty with titanium total ossicular replacement prosthesis: anatomic and functional results

Rodrigo Iñiguez-Cuadra, Isam Alobid, Antonio Borés-Domenech, Luis-Miguel Menéndez-Colino, Miguel Caballero-Borrego, Manuel Bernal-Sprekelsen
Otology & Neurotology 2010, 31 (3): 409-14
20042992

OBJECTIVE: To evaluate anatomical and functional results using titanium prostheses in cartilage palisade tympanoplasties.

STUDY DESIGN: Retrospective clinical study. Data were collected from patients' charts and clinical review.

SETTING: Tertiary referral center.

INTERVENTION: Cartilage tympanoplasty with titanium total ossicular replacement prosthesis after tympanoplasty or tympanomastoidectomy in patients operated on between July 1998 and February 2006.

MAIN OUTCOME MEASURES: Anatomical results (closure of the perforation, rate of retraction pockets, recurrent cholesteatoma, and extrusion and re-perforation rates) were clinically evaluated. Pure-tone averages of air and bone conduction were analyzed. A postoperative air-bone gap (ABG) of 20 dB or less was taken to represent successful hearing.The hearing outcomes of canal wall up (CWU), canal wall down (CWD), primary and revision surgeries, and 2 groups of a short-term (<12 mo) or long-term (>24 mo) follow-up (f-u) were assessed and compared.

RESULTS: Ninety-four cases were observed during the visiting period: 43 (45.7%) underwent primary procedures and 51 (54.3%) underwent revision surgeries. Closure of the tympanic membrane was achieved in 98.9%.Postoperative ABG was 20 dB or lower in 62 (66%) of 93 cases, between 11 and 20 dB in 33 cases (35%), and 10 dB or lower in 29 cases (31%).All cases undergoing CWU had a mean +/- SD postoperative ABG of 14.59 +/- 11.28 dB. There were no statistically significant differences (independent-samples t test, p = 0.5) between these patients and those receiving CWD surgery (15.95 +/- 10 dB).Thirty-eight (68%) of 56 CWD and 24 (64%) of 37 CWU cases achieved a postoperative ABG between 0 and 20 dB (chi = 0.08, p = 0.7, correlation = 0.031).Thirty-three (64.7%) of 51 who underwent revision surgeries and 29 (69%) of 42 who underwent primary procedures had a postoperative ABG between 0 and 20 dB. The difference between the groups was not significant (chi = 0.3, correlation = 0.058, p = 0.5).The mean ABG in the short f-u group was 12.38 +/- 7.34. There was no significant difference regarding long-term f-u after 24 months (11.76 +/- 8.9; Wilcoxon signed-rank test, p = 0.7).We compared the mean postoperative ABG in low hearing frequencies (500 and 1,000 Hz) and high hearing frequencies (2,000 and 4,000 Hz). A better sound transmission was achieved in high frequencies (10.32 +/- 10.6 versus 20.61 +/- 13.73 dB, respectively); the difference was statistically significant (p < 0.001, paired-samples t test).

CONCLUSION: Our results suggest that tympanoplasty with titanium total ossicular replacement prosthesis reconstruction offers a stable improvement of the ABG less than 20 dB in 66% of cases, in both short-term and long-term f-u. There were no differences in the results between CWU and CWD or between primary and revision surgery. The titanium prosthesis achieves the best acoustical results for sound transmission at high frequencies (2,000 and 4,000 Hz).

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
20042992
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"