PURPOSE: To prospectively determine whether cardiac-gated multidetector computed tomography (CT) allows visualization of aortic valve leaflets after bioprosthetic aortic valve replacement (AVR), to provide an accurate method for measuring the aortic valve opening, and to provide morphologic and functional information regarding the mechanism underlying poor function of the bioprosthetic valve.

MATERIALS AND METHODS: The institutional review board approved the study protocol; informed consent was given. Fifty-four patients (27 men; mean age, 75 years + or - 8 [standard deviation]) with bioprosthetic AVR implanted 2 years + or - 3 earlier underwent 64-section CT and transthoracic echocardiography (TTE). Two blinded observers manually planimetered the aortic valve area (AVA) by using a computer workstation on end-systolic short-axis CT images and measured opening angles (OAs) between the bioprosthesis annulus base and the free margin on long-axis images. These measurements were compared with those of the effective orifice area (EOA) of the valve at Doppler continuity-equation TTE by using regression and Bland-Altman methods. Morphology and mobility of leaflets in normally functioning (EOA indexed to body surface area [EOA(i)] > 0.65 cm(2)/m(2)) and dysfunctional (EOA(i)< 0.65 cm(2)/m(2)) AVRs were compared.

RESULTS: AVA at CT correlated highly to EOA at TTE (r = 0.93, P < .001) but was significantly larger (1.2 cm(2) + or - 0.4 vs 1.1 cm(2) + or - 0.3, P < .001) than EOA at TTE. In dysfunctional bioprostheses (n = 34), CT results showed a variety of morphologic abnormalities, such as leaflet thickening (n = 9), presumed thrombotic material (n = 6), and leaflet calcification (n = 1). Multidetector CT results demonstrated restriction of leaflet motion indicated by lower OA (64 degrees + or - 5 vs 79 degrees + or - 3, P < .0001) in dysfunctional AVRs than in normally functioning AVRs (n = 11).

CONCLUSION: Sixty-four-section CT can help accurately measure AVA in bioprosthetic AVR compared with EOA at TTE. It can also show morphologic abnormalities and reduced leaflet motion in a dysfunctional bioprosthesis, thereby potentially unraveling the mechanism of dysfunction.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app