Circulation 2009 December 2
BACKGROUND: The Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) demonstrated that implantable cardioverter-defibrillator (ICD) therapy reduces all-cause mortality in patients with New York Heart Association class II/III heart failure and a left ventricular ejection fraction < or =35% on optimal medical therapy. Whether ICD therapy reduced sudden death caused by ventricular tachyarrhythmias without affecting heart failure deaths in this population is unknown.

METHODS AND RESULTS: SCD-HeFT randomized 2521 subjects to placebo, amiodarone, or shock-only, single-lead ICD therapy. Over a median follow-up of 45.5 months, a total of 666 deaths occurred, which were reviewed by an Events Committee and initially categorized as cardiac or noncardiac. Cardiac deaths were further adjudicated as resulting from sudden death presumed to be ventricular tachyarrhythmic, bradyarrhythmia, heart failure, or other cardiac causes. ICD therapy significantly reduced cardiac mortality compared with placebo (adjusted hazard ratio, 0.76; 95% confidence interval, 0.60 to 0.95) and tachyarrhythmia mortality (adjusted hazard ratio, 0.40; 95% confidence interval, 0.27 to 0.59) and had no impact on mortality resulting from heart failure or noncardiac causes. The cardiac and tachyarrhythmia mortality reductions were evident in subjects with New York Heart Association class II but not in subjects with class III heart failure. The reduction in tachyarrhythmia mortality with ICD therapy was similar in subjects with ischemic and nonischemic disease. Compared with placebo, amiodarone had no significant effect on any mode of death.

CONCLUSIONS: ICD therapy reduced cardiac mortality and sudden death presumed to be ventricular tachyarrhythmic in SCD-HeFT and had no effect on heart failure mortality. Amiodarone had no effect on all-cause mortality or its cause-specific components, except an increase in non-cardiac mortality in class III patients. [corrected]

CLINICAL TRIAL REGISTRATION INFORMATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00000609.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app