Cerebral venous thrombosis: diagnostic accuracy of combined, dynamic and static, contrast-enhanced 4D MR venography.
AJNR. American Journal of Neuroradiology 2010 March
BACKGROUND AND PURPOSE: MR including MRV is an established method to diagnose CVT. However, it remains unsettled which MR imaging modalities offer the highest diagnostic accuracy. We evaluated the accuracy of a combined, dynamic (1.5 seconds per dataset) and static (voxel size, 1.1 x 0.9 x 1.5 mm), contrast-enhanced MRV method (combo-4D MRV) relative to other established MR/MRV modalities.
MATERIALS AND METHODS: A total of 39 patients with CVT (n = 20) and control subjects (n = 19) underwent combo-4D MRV, 2D TOF MRV, GRE imaging, and T2W imaging. For these modalities, diagnostic accuracy (ROCs) for CVT affecting 53 out of 234 predefined venous segments was determined. Sensitivity and specificity were separately calculated for different stages of CVT (acute/subacute/chronic).
RESULTS: Combo-4D MRV showed the highest accuracy (AUC, 0.99 [95% CI, 0.97-1.0]; sensitivity, 97% [84%-100%]) for thrombosed dural sinuses. For all thrombosed segments including cortical veins, its sensitivity was best (76% [64%-84%]; AUC, 0.92 [0.88-0.96]), followed by TOF MRV (72% [59%-81%]; AUC, 0.93 [0.88-0.97]). Even for chronic CVT, it showed a relatively high sensitivity of 67% (30%-90%). For thrombosed cortical veins alone, GRE images achieved the highest sensitivity (66% [46%-81%]; AUC, 0.88 [0.78-0.97]). Specificities of all modalities ranged from 96% to 99%.
CONCLUSIONS: Combo-4D MRV showed an excellent accuracy for the diagnosis of dural sinus thrombosis. The analysis of dynamic patterns of contrast enhancement in dural sinuses appeared useful to identify chronic thrombosis. To diagnose thrombosed cortical veins, GRE images should primarily be analyzed.
MATERIALS AND METHODS: A total of 39 patients with CVT (n = 20) and control subjects (n = 19) underwent combo-4D MRV, 2D TOF MRV, GRE imaging, and T2W imaging. For these modalities, diagnostic accuracy (ROCs) for CVT affecting 53 out of 234 predefined venous segments was determined. Sensitivity and specificity were separately calculated for different stages of CVT (acute/subacute/chronic).
RESULTS: Combo-4D MRV showed the highest accuracy (AUC, 0.99 [95% CI, 0.97-1.0]; sensitivity, 97% [84%-100%]) for thrombosed dural sinuses. For all thrombosed segments including cortical veins, its sensitivity was best (76% [64%-84%]; AUC, 0.92 [0.88-0.96]), followed by TOF MRV (72% [59%-81%]; AUC, 0.93 [0.88-0.97]). Even for chronic CVT, it showed a relatively high sensitivity of 67% (30%-90%). For thrombosed cortical veins alone, GRE images achieved the highest sensitivity (66% [46%-81%]; AUC, 0.88 [0.78-0.97]). Specificities of all modalities ranged from 96% to 99%.
CONCLUSIONS: Combo-4D MRV showed an excellent accuracy for the diagnosis of dural sinus thrombosis. The analysis of dynamic patterns of contrast enhancement in dural sinuses appeared useful to identify chronic thrombosis. To diagnose thrombosed cortical veins, GRE images should primarily be analyzed.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app