COMPARATIVE STUDY
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Microbial contamination of syringes during preparation: the direct influence of environmental cleanliness and risk manipulations on end-product quality.

PURPOSE: The direct influence of environmental cleanliness and risk manipulations on prepared syringes was evaluated.

METHODS: Media-fill testing was used to estimate potential microbial contamination. Syringes were prepared in three different environments using four different uncontrolled high-risk manipulations. The three environments included an International Organization for Standardization (ISO) class 5 horizontal laminar-airflow hood in an ISO class 6 cleanroom (in accordance with United States Pharmacopeia [USP] chapter 797), an ISO class 7 drug preparation area of an operating room, and an uncontrolled decentralized pharmacy in a ward. For each combination of environment and manipulation, 100 syringes were filled by a single operator. The four high-risk manipulations used included simple filling of syringes with trypticase soy broth, three-second contact by the ungloved fingers of the operator with the hub of the syringe, three-second contact between an object and the hub of the syringe, and exposure of the filled syringes to ambient air for 10 minutes.

RESULTS: Of the 1500 syringes prepared in three different environments, none produced within the cleanroom contained microorganisms, 6% were contaminated in the operating room, and 16% were contaminated in the ward (p < 0.0001). Certain high-risk manipulations were associated with a significant increase in the contamination of the surrogate syringes, including exposure to nonsterile ambient air and nonsterile objects or fingers (p < 0.0001).

CONCLUSION: High contamination rates were measured when the hub of syringes touched nonsterile environmental surfaces and fingers, whereas the drawn-air manipulation was associated with a lower risk of contamination. Working within a properly operating unidirectional airflow primary engineering control in an ISO class 5 cleanroom in accordance with USP chapter 797 requirements was demonstrated to be the best way to avoid bacterial or fungal contamination of injectable drugs directly resulting in patient infections.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app