Add like
Add dislike
Add to saved papers

Permanent pacemaker implantation after isolated aortic valve replacement: incidence, risk factors and surgical technical aspects.

OBJECTIVES: Conducting system defects are common in patients with aortic valve disease. Aortic valve replacement may result in further conduction abnormalities requiring permanent pacemaker implantation. The aim of our study was to identify the incidence and predictors for postoperative 30-day permanent pacemaker implantation in patients undergoing isolated aortic valve replacement, and the effect of an accurate surgical technique in order to prevent permanent pacemaker implantation.

METHODS: Data from 261 consecutive patients (mean age 69 +/- 12 years, 136 men) undergoing isolated aortic valve replacement from January 2004 to January 2008 were analyzed retrospectively. Indications for aortic valve replacement were aortic valve stenosis (n = 156), stenoinsufficiency (n = 63), regurgitation (n = 42). Aortic bicuspid valve was present in 25% of cases (n = 64), redo operation was the indication in 7% (n = 18). Preoperative conducting system disease, defined as first-degree atrioventricular block, left or right bundle-branch block or left anterior hemiblock, was present in 25.6% (n = 67) of patients. An accurate surgical technique for debridement of calcific material was performed.

RESULTS: In-hospital mortality was 0.8% (2 out of 261 patients). Postoperatively, 8 out of 261 patients (3%) required permanent pacemaker implantation, for second-degree (n = 1) or complete atrioventricular block (n = 7). Incidence of permanent pacemaker implantation was similar for patients either with or without preoperative conducting system disease (25 vs. 25.7%, P = NS). Independent predictors of permanent pacemaker implantation were greater preoperative end-systolic diameter (P = 0.026) and left ventricular septum hypertrophy (P = 0.041).

CONCLUSIONS: Need of permanent pacemaker implantation after aortic valve replacement seems to be related more to preoperative advanced aortic valve disease rather than pre-existing conducting system abnormalities. An accurate surgical technique for aortic valve replacement probably helps to prevent further impairment of conducting system function requiring early postoperative permanent pacemaker implantation.

Full text links

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app