We have located links that may give you full text access.
Journal Article
Multicenter Study
Randomized Controlled Trial
Research Support, Non-U.S. Gov't
Cardiac-resynchronization therapy for the prevention of heart-failure events.
New England Journal of Medicine 2009 October 1
BACKGROUND: This trial was designed to determine whether cardiac-resynchronization therapy (CRT) with biventricular pacing would reduce the risk of death or heart-failure events in patients with mild cardiac symptoms, a reduced ejection fraction, and a wide QRS complex.
METHODS: During a 4.5-year period, we enrolled and followed 1820 patients with ischemic or nonischemic cardiomyopathy, an ejection fraction of 30% or less, a QRS duration of 130 msec or more, and New York Heart Association class I or II symptoms. Patients were randomly assigned in a 3:2 ratio to receive CRT plus an implantable cardioverter-defibrillator (ICD) (1089 patients) or an ICD alone (731 patients). The primary end point was death from any cause or a nonfatal heart-failure event (whichever came first). Heart-failure events were diagnosed by physicians who were aware of the treatment assignments, but they were adjudicated by a committee that was unaware of assignments.
RESULTS: During an average follow-up of 2.4 years, the primary end point occurred in 187 of 1089 patients in the CRT-ICD group (17.2%) and 185 of 731 patients in the ICD-only group (25.3%) (hazard ratio in the CRT-ICD group, 0.66; 95% confidence interval [CI], 0.52 to 0.84; P=0.001). The benefit did not differ significantly between patients with ischemic cardiomyopathy and those with nonischemic cardiomyopathy. The superiority of CRT was driven by a 41% reduction in the risk of heart-failure events, a finding that was evident primarily in a prespecified subgroup of patients with a QRS duration of 150 msec or more. CRT was associated with a significant reduction in left ventricular volumes and improvement in the ejection fraction. There was no significant difference between the two groups in the overall risk of death, with a 3% annual mortality rate in each treatment group. Serious adverse events were infrequent in the two groups.
CONCLUSIONS: CRT combined with ICD decreased the risk of heart-failure events in relatively asymptomatic patients with a low ejection fraction and wide QRS complex. (ClinicalTrials.gov number, NCT00180271.)
METHODS: During a 4.5-year period, we enrolled and followed 1820 patients with ischemic or nonischemic cardiomyopathy, an ejection fraction of 30% or less, a QRS duration of 130 msec or more, and New York Heart Association class I or II symptoms. Patients were randomly assigned in a 3:2 ratio to receive CRT plus an implantable cardioverter-defibrillator (ICD) (1089 patients) or an ICD alone (731 patients). The primary end point was death from any cause or a nonfatal heart-failure event (whichever came first). Heart-failure events were diagnosed by physicians who were aware of the treatment assignments, but they were adjudicated by a committee that was unaware of assignments.
RESULTS: During an average follow-up of 2.4 years, the primary end point occurred in 187 of 1089 patients in the CRT-ICD group (17.2%) and 185 of 731 patients in the ICD-only group (25.3%) (hazard ratio in the CRT-ICD group, 0.66; 95% confidence interval [CI], 0.52 to 0.84; P=0.001). The benefit did not differ significantly between patients with ischemic cardiomyopathy and those with nonischemic cardiomyopathy. The superiority of CRT was driven by a 41% reduction in the risk of heart-failure events, a finding that was evident primarily in a prespecified subgroup of patients with a QRS duration of 150 msec or more. CRT was associated with a significant reduction in left ventricular volumes and improvement in the ejection fraction. There was no significant difference between the two groups in the overall risk of death, with a 3% annual mortality rate in each treatment group. Serious adverse events were infrequent in the two groups.
CONCLUSIONS: CRT combined with ICD decreased the risk of heart-failure events in relatively asymptomatic patients with a low ejection fraction and wide QRS complex. (ClinicalTrials.gov number, NCT00180271.)
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app