JOURNAL ARTICLE

A fast and efficient microfluidic system for highly selective one-to-one droplet fusion

Linas Mazutis, Jean-Christophe Baret, Andrew D Griffiths
Lab on a Chip 2009 September 21, 9 (18): 2665-72
19704982
Microdroplets in microfluidic systems can be used as independent microreactors to perform a range of chemical and biological reactions. However, in order to add new reagents to pre-formed droplets at defined times, to start, modify, or terminate a reaction, it is necessary to perform a controlled fusion with a second droplet. We describe and characterize a simple and extremely reliable technique for the one-to-one fusion of droplet pairs in a microfluidic system at kHz frequencies. The technique does not require special channel treatment, electrical fields or lasers to induce droplet fusion. Instead, we make use of transient states in the stabilization of the droplet interface by surfactant, coupled to a proper geometrical design of a coalescence module, to induce the selective fusion of a droplet stabilized by surfactant (re-injected) with a droplet which is not fully stabilized (generated on-chip). Using a 1.2-fold excess of the surfactant-stabilized droplets approximately 99% of the partially stabilized droplets were fused one-to-one with surfactant-stabilized droplets. Even when the surfactant-stablized droplets were in 5-fold excess, over 96% of the partially stabilized droplets were fused one-to-one. The fused droplet contains enough surfactant to inhibit further fusion events. After fusion, the droplets were fully stabilized by additional surfactant provided in the carrier oil, which allowed the fused droplets to be collected, incubated off-chip and re-injected onto a microfluidic device without any undesired coalescence.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
19704982
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"