Percutaneous pinning of distal radius fractures: an anatomic study demonstrating the proximity of K-wires to structures at risk.

PURPOSE: Closed reduction and percutaneous pinning is a reliable technique for treating 2- and 3-part distal radius fractures. There are currently no data that demonstrate the proximity of at-risk nerves and tendons during percutaneous placement of 5 commonly used K-wires. Whereas the previous literature notes the risk of superficial radial nerve injury with K-wire insertion into the radial styloid, the current study provides specific distances, not only to the superficial radial nerve (SRN) but also to the tendons of the first through fifth extensor compartments during K-wire insertion.

METHODS: K-wires (1.5 mm or 0.059 in) were placed percutaneously into the distal radius of 15 cadaver specimens, simulating fixation of a distal radius fracture. After dissection, the distance from the K-wires to the extensor tendons and branches of the SRN were measured and tabulated.

RESULTS: The volar radial styloid K-wire was an average distance of 1.47 mm +/- 1.7 from the closest branch of the SRN. One penetrated a branch of the SRN. The dorsal radial styloid K-wire was an average distance of 0.35 mm +/- 0.64 from the closest branch of the SRN. No tendons in the first compartment were found penetrated by or touching the K-wires. The transverse radial K-wire was an average distance of 1.07 mm +/- 1.57 from the branches or trunk of the SRN. One K-wire was found piercing the volar branch of the SRN, and 1 K-wire was found piercing the abductor pollicis longus. The dorsal rim K-wire was an average of 2.94 mm +/- 2.11 from the ulnar aspect of the extensor pollicis longus and an average of 1.44 mm +/- 1.65 from the radial aspect of the extensor digitorum communis. The dorsoulnar K-wire was an average distance of 1.88 mm +/- 1.6 ulnar or radial to the extensor digiti quinti proprius and penetrated it in three specimens.

CONCLUSIONS: The volar radial styloid, transverse radial, and dorsoulnar K-wires all penetrated either tendons or nerves. It is therefore prudent to make a small incision to identify and protect the underlying structures prior to placement of K-wires used for the fixation of distal radius fractures. Also, care must be taken not to place the dorsal K-wires more than 5 mm ulnar to Lister's tubercle to avoid extensor digitorum communis injury.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app