JOURNAL ARTICLE
VALIDATION STUDIES
Add like
Add dislike
Add to saved papers

Reliability of optic nerve ultrasound for the evaluation of patients with spontaneous intracranial hemorrhage.

Neurocritical Care 2009 December
INTRODUCTION: The aim of our study is to confirm the reliability of optic nerve ultrasound as a method to detect intracranial hypertension in patients with spontaneous intracranial hemorrhage, to assess the reproducibility of the measurement of the optic nerve sheath diameter (ONSD), and to verify that ONSD changes concurrently with intracranial pressure (ICP) variations.

METHODS: Sixty-three adult patients with subarachnoid hemorrhage (n = 34) or primary intracerebral hemorrhage (n = 29) requiring sedation and invasive ICP monitoring were enrolled in a 10-bed multivalent ICU. ONSD was measured 3 mm behind the globe through a 7.5-MHz ultrasound probe. Mean binocular ONSD was used for statistical analysis. ICP values were registered simultaneously to ultrasonography. Twenty-eight ONSDs were measured consecutively by two different observers, and interobserver differences were calculated. Twelve coupled measurements were taken before and within 1 min after cerebrospinal fluid (CSF) drainage to control elevated ICP.

RESULTS: Ninety-four ONSD measurements were analyzed. 5.2 mm proved to be the optimal ONSD cut-off point to predict raised ICP (>20 mmHg) with 93.1% sensitivity (95% CI: 77.2-99%) and 73.85% specificity (95% CI: 61.5-84%). ONSD-ICP correlation coefficient was 0.7042 (95% CI for r = 0.5850-0.7936). The median interobserver ONSD difference was 0.25 mm. CSF drainage to control elevated ICP caused a rapid and significant reduction of ONSD (from 5.89 ± 0.61 to 5 ± 0.33 mm, P < 0.01).

CONCLUSION: Our investigation confirms the reliability of optic nerve ultrasound as a non-invasive method to detect elevated ICP in intracranial hemorrhage patients. ONSD measurements proved to have a good reproducibility. ONSD changes almost concurrently with CSF pressure variations.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app