COMPARATIVE STUDY
JOURNAL ARTICLE

Biomechanical comparison of polyaxial and uniaxial locking plate fixation in a proximal tibial gap model

Aaron B Cullen, Shane Curtiss, Mark A Lee
Journal of Orthopaedic Trauma 2009, 23 (7): 507-13
19633460

OBJECTIVES: Lateral locked plating for proximal tibial fractures with metaphyseal disruption provides a biomechanically stable and biologically favorable alternative to conventional medial/lateral plate fixation. New polyaxial screw technology incorporates expanding screw bushings, allowing variable angle screw placement, while providing angular stability. We hypothesize that polyaxial locking plates will exhibit comparable stiffness, strength to failure, and resistance to plastic deformation to conventional locking plates in a proximal tibial gap model.

METHODS: We stabilized extra-articular metaphyseal gap osteotomies in synthetic composite tibiae with dual medial and lateral plating, Less Invasive Stabilization System (LISS) plates, 4.5-mm proximal tibial lateral locking plates with (LP+) and without (LP-) angled screws, and 4.5-mm polyaxial locking plates with (PA+) and without (PA-) angled screws. All were tested with cyclic, ramped, and axial loading to failure.

RESULTS: No plates demonstrated screw failure before plate failure. Dual-plate constructs did not fail. All lateral plates failed at the osteotomy. LP- failed at low load. PA+ was significantly stiffer (165 +/- 17 N/mm) with greater load to failure (711 +/- 23 N) than all other constructs (PA-: 56 +/- 6 N/mm, 617 +/- 33 N; LP+: 137 +/- 23 N/mm, 488 +/- 39 N; LISS: 76 +/- 5 N/mm, 656 +/- 39 N). PA+ had significantly less plastic deformation (12.1 +/- 0.8 mm) than LP+ (13.4 +/- 3.7 mm), but more than PA- (5.8 +/- 1.2 mm) and LISS (3.9 +/- 0.6 mm). PA- did not differ significantly from LISS in any parameter.

CONCLUSIONS: This study demonstrates that this unique polyaxial locking plate mechanism, when tested in various constructs, exhibits similar biomechanical performance regarding stiffness, strength to failure, and resistance to plastic deformation when compared with uniaxial locking plates. The polyaxial locking plate with an angled screw was stiffest and had the greatest load to failure. The polyaxial locking plate alone tested similar to the LISS. In addition, the benefit of the angled screw for biomechanical stability is demonstrated.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
19633460
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"