Immediate cardiovascular effects of the Taser X26 conducted electrical weapon.
Emergency Medicine Journal : EMJ 2009 August
STUDY OBJECTIVES: To evaluate the immediate cardiac and cardiovascular effects of Taser X26 conducted electrical weapon (CEW) exposure in human volunteers, including heart rhythm, rate and blood pressure.
METHODS: Volunteer police officers participating in CEW training and testing each underwent a 5, 3 and 1 s exposure to the Taser X26 CEW. Continuous electrocardiogram (ECG) monitoring was performed before, during and after each exposure. Blood pressures were measured at rest before and within 1 minute after each exposure. Paired sample t-test analysis and confidence interval calculations were performed.
RESULTS: 84 Taser exposures were monitored among 28 subjects (24 men, four women) with an average age of 34 years (range 24-46, SD 5.6). No cardiac dysrhythmias or aberrantly conducted beats were seen. Mean heart rate increased by 10.9 beats per minute (bpm) (95% CI 8.2 to 13.7) from 121.7 to 132.6 (p<0.001). The QRS and QTc cardiac intervals did not change significantly. Mean blood pressure increased from 138.6/82.8 mm Hg at rest to 145.8/85.6 mm Hg after the standard 5-s CEW discharge.
CONCLUSION: CEW exposure produced no detectable dysrhythmias and a statistically significant increase in heart rate. Overall, Taser CEW exposure appears to be safe and well tolerated from a cardiovascular standpoint in this population. This study increases the cumulative human subject experience of CEW exposure with continuous ECG monitoring and includes 28 full 5-s exposures.
METHODS: Volunteer police officers participating in CEW training and testing each underwent a 5, 3 and 1 s exposure to the Taser X26 CEW. Continuous electrocardiogram (ECG) monitoring was performed before, during and after each exposure. Blood pressures were measured at rest before and within 1 minute after each exposure. Paired sample t-test analysis and confidence interval calculations were performed.
RESULTS: 84 Taser exposures were monitored among 28 subjects (24 men, four women) with an average age of 34 years (range 24-46, SD 5.6). No cardiac dysrhythmias or aberrantly conducted beats were seen. Mean heart rate increased by 10.9 beats per minute (bpm) (95% CI 8.2 to 13.7) from 121.7 to 132.6 (p<0.001). The QRS and QTc cardiac intervals did not change significantly. Mean blood pressure increased from 138.6/82.8 mm Hg at rest to 145.8/85.6 mm Hg after the standard 5-s CEW discharge.
CONCLUSION: CEW exposure produced no detectable dysrhythmias and a statistically significant increase in heart rate. Overall, Taser CEW exposure appears to be safe and well tolerated from a cardiovascular standpoint in this population. This study increases the cumulative human subject experience of CEW exposure with continuous ECG monitoring and includes 28 full 5-s exposures.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app