JOURNAL ARTICLE

Validation study of a receptor-based lateral flow assay for detection of beta-lactam antibiotics in milk

Mohamed Abouzied, Michael Sarzynski, Aaron Walsh, Heather Wood, Mark Mozola
Journal of AOAC International 2009, 92 (3): 959-74
19610391
A validation study designed to meet the requirements of the AOAC Research Institute and the U.S. Food and Drug Administration (FDA), Center for Veterinary Medicine, was conducted for a receptor-based, immunochromatographic method (BetaStar US) for detection of beta-lactam antibiotic residues in raw, commingled bovine milk. The assay was found to detect amoxicillin, ampicillin, cephapirin, cloxacillin, and penicillin G at levels below the FDA tolerance/safe levels but above the maximum sensitivity thresholds established by the National Conference on Interstate Milk Shipments. Results of the Part I (internal) and Part II (independent laboratory) dose-response studies using spiked samples were in very close agreement for all five drugs tested, with differences between the Part I and Part II 90/95% sensitivity values ranging from 0 to 1 ppb. The test was able to detect all five drugs at the approximate 90/95% sensitivity levels when present as incurred residues in milk collected from cows that had been treated with the specific drug. A sixth drug, ceftiofur, was found to be undetectable at levels of < or = 500 ppb (as total ceftiofur metabolites from incurred residues in milk samples). The selectivity of the assay was 100%, because no false-positive results were obtained in tests of >1000 control milk samples. The assay was found to be applicable to the testing of frozen raw milk samples. Results of ruggedness experiments established the operating parameter tolerances for the BetaStar US assay. Results of cross-reactivity testing established that the assay detects certain other beta-lactam drugs (dicloxacillin and ticarcillin), but it does not cross-react with any of 30 drugs belonging to other classes. Abnormally high bacterial or somatic cell counts in raw milk produced no interference with the ability of the test to detect beta-lactams at tolerance/safe levels.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Trending Papers

Remove bar
Read by QxMD icon Read
19610391
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"