Add like
Add dislike
Add to saved papers

Sensitivity of dose-finding studies to observation errors.

The purpose of Phase I designs is to estimate the MTD (maximum tolerated dose, in practice a dose with some given acceptable rate of toxicity) while, at the same time, minimizing the number of patients treated at doses too far removed from the MTD. Our purpose here is to investigate the sensitivity of conclusions from dose-finding designs to recording or observation errors. Certain toxicities may go undetected and, conversely, certain non-toxicities may be incorrectly recorded as dose-limiting toxicities. Recording inaccuracies would be expected to have an influence on final and within trial recommendations and, in this paper, we study in greater depth this question. We focus, in particular on three designs used currently; the standard '3+3' design, the grouped up-and-down design [M. Gezmu, N. Flournoy, Group up-and-down designs for dose finding. Journal of Statistical Planning and Inference 2006; 136 (6): 1749-1764.] and the continual reassessment method (CRM, [J. O'Quigley, M. Pepe, L. Fisher, Continual reassessment method: a practical design for phase 1 clinical trials in cancer. Biometrics 1990; 46 (1): 33-48.]). A non-toxicity incorrectly recorded as a toxicity (error of first kind) has a greater influence in general than the converse (error of second kind). These results are illustrated via figures which suggest that the standard '3+3' design in particular is sensitive to errors of the second kind. Such errors can have a very important impact on drug development in that, if carried through to the Phase 2 and Phase 3 studies, we can significantly increase the probability of failure to detect efficacy as a result of having delivered an inadequate dose.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app