INTRODUCTION: Friction measurements in orthodontics are often derived from models by using brackets placed on flat models with various straight wires. Dental arches are convex in some areas. The objectives of this study were to compare the frictional forces generated in conventional flat and convex dental arch setups, and to evaluate the effect of different archwires on friction in both dental arch models.

METHODS: Two stainless steel models were designed and manufactured simulating flat and convex maxillary right buccal dental arches. Five stainless steel brackets from the maxillary incisor to the second premolar (slot size, 0.22 in, Victory, 3M Unitek, Monrovia, Calif) and a first molar tube were aligned and clamped on the metal model at equal distances of 6 mm. Four kinds of orthodontic wires were tested: (1) A. J. Wilcock Australian wire (0.016 in, G&H Wire, Hannover, Germany); and (2) 0.016 x 0.022 in, (3) 0.018 x 0.022 in, and (4) 0.019 x 0.025 in (3M Unitek GmbH, Seefeld, Germany). Gray elastomeric modules (Power O 110, Ormco, Glendora, Calif) were used for ligation. Friction tests were performed in the wet state with artificial saliva lubrication and by pulling 5 mm of the whole length of the archwire. Six measurements were made from each bracket-wire combination, and each test was performed with new combinations of materials for both arch setups (n = 48, 6 per group) in a universal testing machine (crosshead speed: 20 mm/min).

RESULTS AND CONCLUSIONS: Significant effects of arch model (P = 0.0000) and wire types (P = 0.0000) were found. The interaction term between the tested factors was not significant (P = 0.1581) (2-way ANOVA and Tukey test). Convex models resulted in significantly higher frictional forces (1015-1653 g) than flat models (680-1270 g) (P <0.05). In the flat model, significantly lower frictional forces were obtained with wire types 1 (679 g) and 3 (1010 g) than with types 2 (1146 g) and 4 (1270 g) (P <0.05). In the convex model, the lowest friction was obtained with wire types 1 (1015 g) and 3 (1142 g) (P >0.05). Type 1 wire tended to create the least overall friction in both flat and convex dental arch simulation models.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app