Add like
Add dislike
Add to saved papers

Development of robust quantitative methods by near-infrared spectroscopy for rapid pharmaceutical determination of content uniformity in complex tablet matrix.

Analyst 2009 July
Robust NIR transmission spectroscopic methods have been developed for determination of content uniformity (CU) of pharmaceutical products with a complex tablet matrix. The tablets of interest, formulated with eight components with active drug load of approximately 30% (w/w), are non-film coated, embossed, and round with thickness values of 3.6 and 5.6 mm, for the 125 and 500 mg dosage strength, respectively. The calibration data set contained seven laboratory scale batches of tablets with concentration range of active pharmaceutical ingredients (API) varying from 85 to 115% relative to label claim (LC) as well as four full scale production batches of tablets that included the natural physical variability of tablets. The reference concentration values were established by a high performance liquid chromatographic method. Partial least-squares (PLS) regression method was used to generate the calibration models. The root mean squared error of calibration for 125 and 500 mg was 1.6 and 1.5% in LC, respectively. The calibration models were validated in terms of measurement accuracy, repeatability, precision, robustness and transferability. Robustness assessment involved challenging the model with tablets incorporating variations in hardness, excipient vendors, excipient content and excipient particle size. The methods exhibited excellent measurement accuracy based on 87 batches (ten tablets for each batch) evaluated. The transferability of the developed NIR methods was demonstrated by comparing the NIR CU results associated with the same set of tablets scanned at the development site with those scanned at the production site. The result indicates that the NIR method can be used as a suitable alternative to the HPLC method for rapid tablet CU release test in pharmaceuticals.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app