Journal Article
Research Support, N.I.H., Extramural
Add like
Add dislike
Add to saved papers

Long-term outcomes in individuals with prolonged PR interval or first-degree atrioventricular block.

JAMA 2009 June 25
CONTEXT: Prolongation of the electrocardiographic PR interval, known as first-degree atrioventricular block when the PR interval exceeds 200 milliseconds, is frequently encountered in clinical practice.

OBJECTIVE: To determine the clinical significance of PR prolongation in ambulatory individuals.

DESIGN, SETTING, AND PARTICIPANTS: Prospective, community-based cohort including 7575 individuals from the Framingham Heart Study (mean age, 47 years; 54% women) who underwent routine 12-lead electrocardiography. The study cohort underwent prospective follow-up through 2007 from baseline examinations in 1968-1974. Multivariable-adjusted Cox proportional hazards models were used to examine the associations of PR interval with the incidence of arrhythmic events and death.

MAIN OUTCOME MEASURES: Incident atrial fibrillation (AF), pacemaker implantation, and all-cause mortality.

RESULTS: During follow-up, 481 participants developed AF, 124 required pacemaker implantation, and 1739 died. At the baseline examination, 124 individuals had PR intervals longer than 200 milliseconds. For those with PR intervals longer than 200 milliseconds compared with those with PR intervals of 200 milliseconds or shorter, incidence rates per 10 000 person-years were 140 (95% confidence interval [CI], 95-208) vs 36 (95% CI, 32-39) for AF, 59 (95% CI, 40-87) vs 6 (95% CI, 5-7) for pacemaker implantation, and 334 (95% CI, 260-428) vs 129 (95% CI, 123-135) for all-cause mortality. Corresponding absolute risk increases were 1.04% (AF), 0.53% (pacemaker implantation), and 2.05% (all-cause mortality) per year. In multivariable analyses, each 20-millisecond increment in PR was associated with an adjusted hazard ratio (HR) of 1.11 (95% CI, 1.02-1.22; P = .02) for AF, 1.22 (95% CI, 1.14-1.30; P < .001) for pacemaker implantation, and 1.08 (95% CI, 1.02-1.13; P = .005) for all-cause mortality. Individuals with first-degree atrioventricular block had a 2-fold adjusted risk of AF (HR, 2.06; 95% CI, 1.36-3.12; P < .001), 3-fold adjusted risk of pacemaker implantation (HR, 2.89; 95% CI, 1.83-4.57; P < .001), and 1.4-fold adjusted risk of all-cause mortality (HR, 1.44, 95% CI, 1.09-1.91; P = .01).

CONCLUSION: Prolongation of the PR interval is associated with increased risks of AF, pacemaker implantation, and all-cause mortality.

Full text links

We have located open access text paper links.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app