Magnetic resonance imaging after most common form of concussion.
BMC Medical Imaging 2009 June 18
BACKGROUND: Until now there is a lack of carefully controlled studies with conventional MR imaging performed exclusively in concussion with short lasting loss of consciousness (LOC).
METHODS: A MR investigation was performed within 24 hours and after 3 months in 20 patients who had suffered a concussion with a verified loss of consciousness of maximally 5 minutes. As a control group, 20 age- and gender matched patients with minor orthopaedic injuries had a MR investigation using the same protocol.
RESULTS: In a concussion population with an average LOC duration of 1. 4 minutes no case with unequivocal intracranial traumatic pathology was detected.
CONCLUSION: An ordinary concussion with short lasting LOC does not or only seldom result in a degree of diffuse axonal injury (DAI) that is visualized by conventional MR with field strength of 1.0 Tesla (T). Analysis of earlier MR studies in concussion using field strength of 1.5 T as well as of studies with diffusion tensor MR imaging (MR DTI) reveal methodological shortcomings, in particular use of inadequate control groups. There is, therefore, a need for carefully controlled studies using MR of higher field strength and/or studies with MR DTI exclusively in common concussion with LOC of maximally 5 minutes.
METHODS: A MR investigation was performed within 24 hours and after 3 months in 20 patients who had suffered a concussion with a verified loss of consciousness of maximally 5 minutes. As a control group, 20 age- and gender matched patients with minor orthopaedic injuries had a MR investigation using the same protocol.
RESULTS: In a concussion population with an average LOC duration of 1. 4 minutes no case with unequivocal intracranial traumatic pathology was detected.
CONCLUSION: An ordinary concussion with short lasting LOC does not or only seldom result in a degree of diffuse axonal injury (DAI) that is visualized by conventional MR with field strength of 1.0 Tesla (T). Analysis of earlier MR studies in concussion using field strength of 1.5 T as well as of studies with diffusion tensor MR imaging (MR DTI) reveal methodological shortcomings, in particular use of inadequate control groups. There is, therefore, a need for carefully controlled studies using MR of higher field strength and/or studies with MR DTI exclusively in common concussion with LOC of maximally 5 minutes.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app