Vascular enhancement in early dynamic liver MR imaging in an animal model: comparison of two injection regimen and two different doses Gd-EOB-DTPA (gadoxetic acid) with standard Gd-DTPA

Christoph J Zech, Bernhard Vos, Anders Nordell, Matthias Urich, Lennart Blomqvist, Josy Breuer, Maximilian F Reiser, Hanns-Joachim Weinmann
Investigative Radiology 2009, 44 (6): 305-10
19462484

OBJECTIVES: To investigate the influence of 2 different doses and injection rates on the enhancement of liver vasculature in Gd-EOB-DTPA enhanced liver MRI compared with the standard dose Gd-DTPA.

MATERIALS AND METHODS: This animal experimental study has been approved by the local authorities. In 5 pigs, a time-resolved T1w 3D GRE sequence, and in a second experiment, a single-slice turbo FLASH T1w sequence with 3 frames/s were started each with contrast agent application of Gd-EOB-DTPA and Gd-DTPA. Three sets with different doses were performed with an injection rate of 1 and 2 mL/s which are as follows: A, Standard dose: 25 [mu]mol Gd-EOB-DTPA/kg body-weight (bw); B, Double dose: 50 [mu]mol Gd-EOB-DTPA/kg bw; and C, Standard dose: 100 [mu]mol Gd-DTPA/kg bw. Signal intensities were measured in aorta, vena cava inferior, portal vein, and liver parenchyma, and time-signal-to-noise (SNR)-curves were generated. The increase in SNR from baseline and several perfusion parameters were calculated. Statistical significance was tested with the Wilcoxon rank test at a significance level of P = 0.05.

RESULTS: Mean peak enhancement (SNR) in the aorta was not significantly different for set A, B, and C with the same injection rate. Mean peak enhancement in the aorta was significantly higher for set A at 1 mL/s than at 2 mL/s (159.1 vs. 144.4, P = 0.043). Mean peak enhancement in the PV, the vena cava inferior, and the liver parenchyma was significantly lower for set A compared with set B and set C, at both injection speeds. The full width at half max was significantly longer for injection protocols with 1 as compared with 2 mL/s for sets A and set B. Set A with 1 mL/s reached similar values as compared with set C with 2 mL/s for the full width at half max (8.92 vs. 9.40; P = 0.35), for the area-under-the curve (1736.64 vs. 1912.74; P = 0.69) and the maximal signal-to-noise ratio (25.21 vs. 25.37; P = 0.69).

CONCLUSION: Despite the lower amount of gadolinium in the standard dose of Gd-EOB-DTPA, the results showed that the arterial enhancement in Gd-EOB-DTPA-enhanced dynamic liver MRI was comparable to Gd-DTPA. This result can be explained mainly by the higher relaxivity. Choosing a lower injection rate additionally supported to compensate for the lower injection volume by stretching the bolus without decreasing the peak. In this respect, an injection rate of 1 mL/s showed better results with regard to the arterial enhancement compared with 2 mL/s.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Available on the App Store

Available on the Play Store
Remove bar
Read by QxMD icon Read
19462484
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"