JOURNAL ARTICLE
MULTICENTER STUDY
VALIDATION STUDIES
Add like
Add dislike
Add to saved papers

Potential impact of adjusting the threshold of the quantitative D-dimer based on pretest probability of acute pulmonary embolism.

OBJECTIVES: The utility of D-dimer testing for suspected pulmonary embolism (PE) can be limited by test specificity. The authors tested if the threshold of the quantitative D-dimer can be varied according to pretest probability (PTP) of PE to increase specificity while maintaining a negative predictive value (NPV) of >99%.

METHODS: This was a prospective, observational multicenter study of emergency department (ED) patients in the United States. Eligible patients had a diagnostic study ordered to evaluate possible PE. PTP was determined by the clinician's unstructured estimate and the Wells score. Five different D-dimer assays were used. D-dimer test performance was measured using 1) standard thresholds and 2) variable threshold values: twice (for low PTP patients), equal (intermediate PTP patients), or half (high PTP patients) of standard threshold. Venous thromboembolism (VTE) within 45 days required positive imaging plus decision to treat.

RESULTS: The authors enrolled 7,940 patients tested for PE, and clinicians ordered a quantitative D-dimer for 4,357 (55%) patients who had PTPs distributed as follows: low (74%), moderate (21%), or high (4%). At standard cutoffs, across all PTP strata, quantitative D-dimer testing had a test sensitivity of 94% (95% confidence interval [CI] = 91% to 97%), specificity of 58% (95% CI = 56% to 60%), and NPV of 99.5% (95% CI = 99.1% to 99.7%). If variable cutoffs had been used the overall sensitivity would have been 88% (95% CI = 83% to 92%), specificity 75% (95% CI = 74% to 76%), and NPV 99.1% (95% CI = 98.7% to 99.4%).

CONCLUSIONS: This large multicenter observational sample demonstrates that emergency medicine clinicians currently order a D-dimer in the majority of patients tested for PE, including a large proportion with intermediate PTP and high PTP. Varying the D-dimer's cutoff according to PTP can increase specificity with no measurable decrease in NPV.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app