Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions

Eric E C de Waal, Steffen Rex, Cas L J J Kruitwagen, Cor J Kalkman, Wolfgang F Buhre
Critical Care Medicine 2009, 37 (2): 510-5
19114886

OBJECTIVE: Dynamic preload indicators like pulse pressure variation (PPV) and stroke volume variation (SVV) are increasingly being used for optimizing cardiac preload since they have been demonstrated to predict fluid responsiveness in a variety of perioperative settings. However, in open-chest conditions, the value of these indices has not been systematically examined yet. We, therefore, evaluated the ability of PPV and SVV to predict fluid responsiveness under open- and closed-chest conditions.

DESIGN: Prospective, controlled, clinical study.

SETTING: University hospital.

PATIENTS: Twenty-two patients scheduled for elective coronary artery bypass graft surgery.

INTERVENTIONS: Defined volume loads (VL) (10 mL kg-1 hydroxyethyl starch 6%) intra- and postoperatively.

MEASUREMENTS AND MAIN RESULTS: Stroke volume index was measured 1) before and after a VL intraoperatively in open-chest conditions, and 2) under closed-chest conditions within 1 hour after arrival in the intensive care unit. Central venous pressure and global end diastolic volume were assessed as static preload indicators. In addition, PPV and SVV (both obtained with PiCCO system) were recorded. Fluid-responders were defined by an increase in stroke volume index >or=12% subsequent to the VL. Receiver operating characteristic analysis showed that all preload indicators failed to predict fluid responsiveness in open-chest conditions. Under closed-chest conditions, the areas under the receiver operating characteristic curve for PPV and SVV were 0.884 (p = 0.004) and 0.911 (p = 0.003), respectively, whereas the static and volumetric preload parameters failed to predict fluid responsiveness. A PPV of >or=10% identified fluid-responders with a sensitivity of 64% and a specificity of 100%, while a SVV of >8% identified fluid-responders with a sensitivity of 100% and a specificity of 78%.

CONCLUSIONS: Our results suggest that the dynamic preload indicators PPV and SVV are able to predict fluid responsiveness under closed-chest conditions, whereas all static and dynamic preload indicators fail to predict fluid responsiveness under open-chest conditions.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
19114886
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"