We have located links that may give you full text access.
Comparative Study
Journal Article
[Comparative study of ultrasonography, magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography in common duct stones].
Zhonghua Wai Ke za Zhi [Chinese Journal of Surgery] 2008 October 2
OBJECTIVE: To compare the diagnostic value study the technique of ultrasonography, magnetic resonance cholangiopancreatography (MRCP) and endoscopic retrograde cholangiopancreatography (ERCP) in common duct stones.
METHODS: Three hundreds and eighty-four patients suspected common duct stones from August 2005 to October 2007 were undergone abdominal ultrasonography, MRCP and ERCP.
RESULTS: There was stone in common duct in 370 and no stones in 14 of 384 patients. Ultrasonography indicated stones 268 cases, 8 false positive result was among them. MRCP diagnosed stones in 362 cases and false positive result in 6 cases, ERCP diagnosed stones 370 cases. The diagnostic accuracy of ultrasonography, MRCP and ERCP was 70.3% (260/370), 96.2% (356/370) and 100% respectively.
CONCLUSIONS: The diagnostic accuracy of ultrasonography for common duct stone was little higher, US should be used as a primary checking method. There was higher concordance between MRCP and ERCP for common duct stone. Combination of MRCP and ERCP can improve diagnostic accuracy of common duct stone.
METHODS: Three hundreds and eighty-four patients suspected common duct stones from August 2005 to October 2007 were undergone abdominal ultrasonography, MRCP and ERCP.
RESULTS: There was stone in common duct in 370 and no stones in 14 of 384 patients. Ultrasonography indicated stones 268 cases, 8 false positive result was among them. MRCP diagnosed stones in 362 cases and false positive result in 6 cases, ERCP diagnosed stones 370 cases. The diagnostic accuracy of ultrasonography, MRCP and ERCP was 70.3% (260/370), 96.2% (356/370) and 100% respectively.
CONCLUSIONS: The diagnostic accuracy of ultrasonography for common duct stone was little higher, US should be used as a primary checking method. There was higher concordance between MRCP and ERCP for common duct stone. Combination of MRCP and ERCP can improve diagnostic accuracy of common duct stone.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices