Hemodynamic energy delivery of the pulsatile flow in a simulated pediatric extracorporeal circuit.

Objectives of this study were 1) to precisely measure the generation and delivery of hemodynamic energy levels during pediatric cardiopulmonary bypass procedure using a simulated circuit and 2) to quantify energy losses of the extracorporeal circuit components. A conventional roller pump, pediatric hollow-fiber membrane oxygenator, arterial filter, arterial cannula, and (1/4)-in tubing were used. The circuit was primed with 40/60 glycerin/water mixture. Postcannula (pseudo patient's pressure) pressure was maintained 40 mm Hg by a Hoffman clamp. All trials were conducted at 800 mL/min of pump flow with pulsatile (n=6) and nonpulsatile (n=6) modes at room temperature. Simultaneous blood flow and pressures at pre/post oxygenator and pre/post cannula sites were recorded. There were gradual decreases in values of circuit mean pressure, energy equivalent pressure, surplus hemodynamic energy, and total hemodynamic energy (THE) from pre- and postoxygenator to pre- and postcannula sites. Approximately 30% of THE generated by roller pump was damped by the membrane oxygenator. About 25% of THE was lost by the arterial filter and the length of the arterial tubing. Only 15%-18% of THE was delivered into the pseudo patient. Although the results of this study showed that the roller pump could provide higher hemodynamic energy per second with pulsatile flow compared with the nonpulsatile flow, the majority (80%) of hemodynamic energy was damped by the components of the extracorporeal circuit.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app