Relative value of pressures and volumes in assessing fluid responsiveness after valvular and coronary artery surgery.

BACKGROUND AND AIMS: Cardiac function may differ after valvular (VS) and coronary artery (CAS) surgery and this may affect assessment of fluid responsiveness. The aim of the study was to compare VS and CAS in the value of cardiac filling pressures and volumes herein.

METHODS: There were eight consecutive patients after VS and eight after CAS, with femoral and pulmonary artery catheters in place. In each patient, five sequential fluid loading steps of 250 ml of colloid each were done. We measured central venous pressure (CVP), pulmonary artery occlusion pressure (PAOP) and, by transpulmonary thermodilution, cardiac index (CI) and global end-diastolic (GEDVI) and intrathoracic blood volume (ITBVI) indices. Fluid responsiveness was defined by a CI increase >5% or >10% per step.

RESULTS: Global ejection fraction was lower and PAOP was higher after VS than CAS. In responding steps after VS (n=9-14) PAOP and volumes increased, while CVP and volumes increased in responding steps (n=12-19) after CAS. Baseline PAOP was lower in responding steps after VS only. Hence, baseline PAOP as well as changes in PAOP and volumes were of predictive value after VS and changes in CVP and volumes after CAS, in receiver operating characteristic curves. After VS, PAOP and volume changes equally correlated to CI changes. After CAS, only changes in CVP and volumes correlated to those in CI.

CONCLUSIONS: While volumes are equally useful in monitoring fluid responsiveness, the predictive and monitoring value of PAOP is greater after VS than after CAS. In contrast, the CVP is of similar value as volume measurements in monitoring fluid responsiveness after CAS. The different value of pressures rather than of volumes between surgery types is likely caused by systolic left ventricular dysfunction in VS. The study suggests an effect of systolic cardiac function on optimal parameters of fluid responsiveness and superiority of the pulmonary artery catheter over transpulmonary dilution, for haemodynamic monitoring of VS patients.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app