Effectiveness of continuous glucose monitoring in pregnant women with diabetes: randomised clinical trial

Helen R Murphy, Gerry Rayman, Karen Lewis, Susan Kelly, Balroop Johal, Katherine Duffield, Duncan Fowler, Peter J Campbell, Rosemary C Temple
BMJ: British Medical Journal 2008, 337: a1680
18818254

OBJECTIVE: To evaluate the effectiveness of continuous glucose monitoring during pregnancy on maternal glycaemic control, infant birth weight, and risk of macrosomia in women with type 1 and type 2 diabetes.

DESIGN: Prospective, open label randomised controlled trial.

SETTING: Two secondary care multidisciplinary obstetric clinics for diabetes in the United Kingdom.

PARTICIPANTS: 71 women with type 1 diabetes (n=46) or type 2 diabetes (n=25) allocated to antenatal care plus continuous glucose monitoring (n=38) or to standard antenatal care (n=33).

INTERVENTION: Continuous glucose monitoring was used as an educational tool to inform shared decision making and future therapeutic changes at intervals of 4-6 weeks during pregnancy. All other aspects of antenatal care were equal between the groups.

MAIN OUTCOME MEASURES: The primary outcome was maternal glycaemic control during the second and third trimesters from measurements of HbA(1c) levels every four weeks. Secondary outcomes were birth weight and risk of macrosomia using birthweight standard deviation scores and customised birthweight centiles. Statistical analyses were done on an intention to treat basis.

RESULTS: Women randomised to continuous glucose monitoring had lower mean HbA(1c) levels from 32 to 36 weeks' gestation compared with women randomised to standard antenatal care: 5.8% (SD 0.6) v 6.4% (SD 0.7). Compared with infants of mothers in the control arm those of mothers in the intervention arm had decreased mean birthweight standard deviation scores (0.9 v 1.6; effect size 0.7 SD, 95% confidence interval 0.0 to 1.3), decreased median customised birthweight centiles (69% v 93%), and a reduced risk of macrosomia (odds ratio 0.36, 95% confidence interval 0.13 to 0.98).

CONCLUSION: Continuous glucose monitoring during pregnancy is associated with improved glycaemic control in the third trimester, lower birth weight, and reduced risk of macrosomia.

TRIAL REGISTRATION: Current Controlled Trials ISRCTN84461581.

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Available on the App Store

Available on the Play Store
Remove bar
Read by QxMD icon Read
18818254
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"