OBJECTIVES: To report our experience with the use of the Amplatzer muscular ventricular septal defect (VSD) occluder, using direct right ventricle free wall puncture for primary closure of muscular VSDs in infants.
BACKGROUND: Young infants with heart failure due to large or multiple muscular VSDs often require intervention at a stage when percutaneous device closure is impractical due to delivery system limitations. There are considerable benefits to avoiding bypass in these infants.
METHODS: Patients with suitable muscular VSDs, considered too small for transvenous closure, underwent periventricular muscular VSD closure under transesophageal echo (TEE) guidance.
RESULTS: Eight infants underwent the procedure. The median age was 14 weeks (2-41) with median weight of 4 kg (3-6.6). Four patients had additional VSDs and one patient had previous repair of coarctation. One patient had dextrocardia and severe left ventricular impairment due to an associated cardiomyopathy. The median VSD size was 8 mm (range, 4-10 mm). A single device (6-12 mm) was deployed in each patient, the size chosen being 1-2 mm larger than the TEE measurement. Two patients had subsequent pulmonary artery banding, with absorbable bands, because of moderate residual shunting through additional VSDs. The latest echo study at a median of 7.2 weeks (0.5-66) post device implantation revealed no patients with a hemodynamically significant shunt.
CONCLUSION: Perventricular muscular VSD closure can be safely and effectively undertaken in small infants with suitable muscular defects, and this strategy can avoid the need for bypass.
BACKGROUND: Young infants with heart failure due to large or multiple muscular VSDs often require intervention at a stage when percutaneous device closure is impractical due to delivery system limitations. There are considerable benefits to avoiding bypass in these infants.
METHODS: Patients with suitable muscular VSDs, considered too small for transvenous closure, underwent periventricular muscular VSD closure under transesophageal echo (TEE) guidance.
RESULTS: Eight infants underwent the procedure. The median age was 14 weeks (2-41) with median weight of 4 kg (3-6.6). Four patients had additional VSDs and one patient had previous repair of coarctation. One patient had dextrocardia and severe left ventricular impairment due to an associated cardiomyopathy. The median VSD size was 8 mm (range, 4-10 mm). A single device (6-12 mm) was deployed in each patient, the size chosen being 1-2 mm larger than the TEE measurement. Two patients had subsequent pulmonary artery banding, with absorbable bands, because of moderate residual shunting through additional VSDs. The latest echo study at a median of 7.2 weeks (0.5-66) post device implantation revealed no patients with a hemodynamically significant shunt.
CONCLUSION: Perventricular muscular VSD closure can be safely and effectively undertaken in small infants with suitable muscular defects, and this strategy can avoid the need for bypass.
Full text links
Trending Papers
Management of Heart Failure With Preserved Ejection Fraction in Elderly Patients: Effectiveness and Safety.Curēus 2023 Februrary
What's New in the Treatment of Non-Alcoholic Fatty Liver Disease (NAFLD).Journal of Clinical Medicine 2023 Februrary 27
BTS clinical statement on aspiration pneumonia.Thorax 2023 Februrary
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app