We have located links that may give you full text access.
Comparative Study
Journal Article
Research Support, Non-U.S. Gov't
Echocardiography-guided pacemaker optimization and radial artery tonometry.
Journal of Cardiac Failure 2008 September
BACKGROUND: Biventricular (Biv) pacemaker optimization is underused because of time and echo skill required. We evaluated radial artery tonometry during echo-guided Biv optimization of atrioventricular (AV) and interventricular (VV) delays.
METHODS AND RESULTS: A total of 60 patients (67 +/- 10 years) underwent simultaneous radial artery tonometry and echocardiography after Biv implant at baseline, short AV delay, and optimal AV delay. Twenty of these also underwent VV optimization. Optimal AV delay was determined by ejection duration (E-dur) of left ventricular (LV) outflow tract by pulsed-waved (PW) Doppler (LV(E-dur)) and mitral inflow PW Doppler pattern and optimal VV delay by LV(E-dur) and tissue Doppler. E-dur was also measured from radial artery pulse wave (RA(E-dur)). AV optimization improved LV(E-dur) from 249 +/- 35 to 260 +/- 38 ms (P < .01) and RA(E-dur) from 276 +/- 31 ms to 284 +/- 32 ms (P = .02). Correlation between LV(E-dur) and by RA(E-dur) was 0.83 (95% CI 0.75-0.92). RA(E-dur) was 282.53 +/- 30 at baseline, 286.65 +/- 36 at optimal AV delay (P < .04 vs. baseline) and 286.90 +/- 35 ms (P < .04 vs. baseline) at optimal AV and VV delay in those who underwent VV optimization.
CONCLUSIONS: AV and VV optimization by echocardiography produces significant improvement in LV(E-dur) and RA(E-dur). Radial artery tonometry may provide a simple noninvasive method to assist in AV delay optimization.
METHODS AND RESULTS: A total of 60 patients (67 +/- 10 years) underwent simultaneous radial artery tonometry and echocardiography after Biv implant at baseline, short AV delay, and optimal AV delay. Twenty of these also underwent VV optimization. Optimal AV delay was determined by ejection duration (E-dur) of left ventricular (LV) outflow tract by pulsed-waved (PW) Doppler (LV(E-dur)) and mitral inflow PW Doppler pattern and optimal VV delay by LV(E-dur) and tissue Doppler. E-dur was also measured from radial artery pulse wave (RA(E-dur)). AV optimization improved LV(E-dur) from 249 +/- 35 to 260 +/- 38 ms (P < .01) and RA(E-dur) from 276 +/- 31 ms to 284 +/- 32 ms (P = .02). Correlation between LV(E-dur) and by RA(E-dur) was 0.83 (95% CI 0.75-0.92). RA(E-dur) was 282.53 +/- 30 at baseline, 286.65 +/- 36 at optimal AV delay (P < .04 vs. baseline) and 286.90 +/- 35 ms (P < .04 vs. baseline) at optimal AV and VV delay in those who underwent VV optimization.
CONCLUSIONS: AV and VV optimization by echocardiography produces significant improvement in LV(E-dur) and RA(E-dur). Radial artery tonometry may provide a simple noninvasive method to assist in AV delay optimization.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app