JOURNAL ARTICLE
Experience of percutaneous mechanical mitral commissurotomy using metallic commissurotome in patients with mitral stenosis at chest disease institute.
BACKGROUND: Percutaneous metallic mitral commissurotomy (PMMC) has been accepted as an alternative to the traditional balloon technique. The advantage of the metallic commissurotome is that it is designed for several reuse and resterization and it is an interesting tool as seen by the authors.
OBJECTIVE: To evaluate the efficacy and safety of PMMC among a wide range of patients with severe mitral stenosis.
MATERIAL AND METHOD: Between July 2000 and August 2003, patients with severe mitral stenosis who underwent PMMC were enrolled Interatrial septum was punctured under transesophageal echocardiography guidance in all cases. Demographic data and baseline characteristics were collected Mitral valve area (MVA) was evaluated by echocardiography and hemodynamic parameters pre and post PMMC were compared
RESULTS: PMMC was performed in 304 patients with a broad range of severe mitral stenosis. Mean age was 38.7 +/- 10. 9 years and 79% was female. Most were in functional class 11 (94%) and 43 patients (14%) had prior commissurotomy. Atrial fibrillation was found in 41%. Twenty-six patients were crossed over to the Inoue balloon technique. The rate of success was 81% in all patients (246/304) and 89% in patients when PMMC was actually done (246/278). The MVA increased from 84 +/- 22 to 170 +/- 36 mm2 (p < 0.0001). Transvalvular gradient decreased from 17 +/- 6 to 7 +/- 4 mmHg (p < 0.0001) and mean left atrial pressure from 26 +/- 7 to 15 +/- 6 mmHg (p < 0.0001). Separation of both commissures was found in 25% and 61% had symptom relief by a reduction in functional class at least one level (p < 0.0001). Complications developed in 16 patients (5.3%) including three serious events, one death caused by severe mitral regurgitation followed by emergency surgery, another survivor after surgical repair of left ventricular free wall rupture and the last one with surgical removal of the malfunctioned device stuck in the left atrium.
CONCLUSION: Results of PMMC is not as encouraging as shown in previous studies. The risk of cardiac tamponade is minimized by interatrial septal puncture using transesophageal echocardiography (TEE) monitoring but this technique increased the possibility of crossover. Deterioration of the metallic commissurotome after a few procedures is demonstrated in the author's real practice.
OBJECTIVE: To evaluate the efficacy and safety of PMMC among a wide range of patients with severe mitral stenosis.
MATERIAL AND METHOD: Between July 2000 and August 2003, patients with severe mitral stenosis who underwent PMMC were enrolled Interatrial septum was punctured under transesophageal echocardiography guidance in all cases. Demographic data and baseline characteristics were collected Mitral valve area (MVA) was evaluated by echocardiography and hemodynamic parameters pre and post PMMC were compared
RESULTS: PMMC was performed in 304 patients with a broad range of severe mitral stenosis. Mean age was 38.7 +/- 10. 9 years and 79% was female. Most were in functional class 11 (94%) and 43 patients (14%) had prior commissurotomy. Atrial fibrillation was found in 41%. Twenty-six patients were crossed over to the Inoue balloon technique. The rate of success was 81% in all patients (246/304) and 89% in patients when PMMC was actually done (246/278). The MVA increased from 84 +/- 22 to 170 +/- 36 mm2 (p < 0.0001). Transvalvular gradient decreased from 17 +/- 6 to 7 +/- 4 mmHg (p < 0.0001) and mean left atrial pressure from 26 +/- 7 to 15 +/- 6 mmHg (p < 0.0001). Separation of both commissures was found in 25% and 61% had symptom relief by a reduction in functional class at least one level (p < 0.0001). Complications developed in 16 patients (5.3%) including three serious events, one death caused by severe mitral regurgitation followed by emergency surgery, another survivor after surgical repair of left ventricular free wall rupture and the last one with surgical removal of the malfunctioned device stuck in the left atrium.
CONCLUSION: Results of PMMC is not as encouraging as shown in previous studies. The risk of cardiac tamponade is minimized by interatrial septal puncture using transesophageal echocardiography (TEE) monitoring but this technique increased the possibility of crossover. Deterioration of the metallic commissurotome after a few procedures is demonstrated in the author's real practice.
Full text links
Trending Papers
Management of Hyponatremia in Heart Failure: Practical Considerations.Journal of Personalized Medicine 2023 January 11
Systemic complications of rheumatoid arthritis: Focus on pathogenesis and treatment.Frontiers in Immunology 2022
2023 American Society of Anesthesiologists Practice Guidelines for Preoperative Fasting: Carbohydrate-containing Clear Liquids with or without Protein, Chewing Gum, and Pediatric Fasting Duration-A Modular Update of the 2017 American Society of Anesthesiologists Practice Guidelines for Preoperative Fasting.Anesthesiology 2023 Februrary 2
Management of heart failure in patients with kidney disease - updates from the 2021 ESC guidelines.Nephrology, Dialysis, Transplantation 2023 January 24
Chronic Kidney Disease, Urinary Tract Infections and Antibiotic Nephrotoxicity: Are There Any Relationships?Medicina 2022 December 28
How I Treat Multiple myeloma in the geriatric patient.Blood 2023 January 25
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app